Plan Review Notes
Plan Review Notes For Permit 15080058
Permit Number 15080058
Review Stop FIRE
Sequence Number 1
Notes
Date Text
2015-08-06 15:15:42THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1. THERE IS INSUFFICIENT DETAIL PROVIDED TO REVIEW OR
 APPROVE THE PROPOSED PROJECT.
  
 2. PROVIDE A WRITTEN DISCRIPTION OR NOTE OUTLINING THE
 INTENT OF THE PROJECT. ARE YOU CREATING A SEPARATE
 OCCUPANCY FOR THE 2ND FLOOR AREA ?
  
 3. PROVIDE ENTIRE BUILDING FOOTPRINT AND FLOORPLAN AND
 CLOUD THE PROPOSED REVISIONS.
  
 4. THE DOOR AT THE BOTTOM OF THE STAIRWELL SWINGS IN.
 THIS IS AN EXIT ACCESS DOOR. WHAT IS THE OCCUPANCY LOAD
 OF THE 2ND FL AREA TO ALLOWING THE DOOR TO SWING
 AGAINST EGRESS.
  
 5. PROVIDE A DOOR SCHEDUE INCLUDING EXIT HARDWARE.
  
 6. REVIEW EXIT REQUIREMENTS OF NFPA CHAPTER 7 ENSURING
 COMPLIANCE UPON LEAVING A PROTECTED ENCLOSED STAIRWEL /
 EXIT PASSAGEWAY NEEDEDL.
  
  