| Plan Review Notes For Permit 15071239 |
| Permit Number |
15071239 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-07-31 17:03:04 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. CODE CHANGED EFFECTIVE JUNE 31, 2015. PROVIDE | | | CURRENT PRODUCT APPROVALS, FAC9N-3. | | | | | | 2. THE ASSEMBLY SELECTED HAS A DESIGN PRESSURE | | | LIMITATION OF -75. THIS IS NOT ADEQUATE FOR ZONES 2/3. | | | IF THIS PRODUCT APPROVAL IS USED, ENGINEERING FOR | | | ENHANCED FASTENING. | | | | | | A CERTAINTEED PRODUCT IS PROPOSED. PLEASE BE ADVISED | | | THAT CERTAINTEED HAS A PRODUCT APPROVAL WHICH INCLUDES | | | ENHANCED FASTENING PATTERNS (SO NO ENGINEERING REQUIRED | | | FOR THAT PRODUCT APPROVAL). | | | | | | |
|