| Plan Review Notes For Permit 15071104 |
| Permit Number |
15071104 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-08-06 11:37:42 | BUILDING PROVISO: | | | SHEET A-7 DETAIL # 1 MICROWAVE MUST MEET: | | | 2014 FBC-ACCESSIBILITY CODE: | | | 309 OPERABLE PARTS | | | 309.2 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR OR GROUND SPACE COMPLYING WITH 305 SHALL | | | BE PROVIDED. | | | | | | 309.3 HEIGHT. | | | OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR MORE OF | | | THE REACH RANGES SPECIFIED IN 308. | | | | | | 309.4 OPERATION. | | | OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND | | | SHALL NOT REQUIRE TIGHT GRASPING, | | | PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED | | | TO ACTIVATE OPERABLE PARTS SHALL | | | BE 5 POUNDS (22.2 N) MAXIMUM. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|