| 2015-07-29 19:44:34 | RESIDENTIAL (R2) FLOORING ALTERATION. BUILDING REVIEW |
| | COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- SOUND INSULATION MATERIAL SUBMITTED: |
| | A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE |
| | DEVELOPED TEST DONE IN ACCORDANCE WITH ASTM E 84 OR UL |
| | 723 AS REQUIRED BY SEC. 720.1 OF FBC 5TH EDITION |
| | (2014). |
| | |
| | B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS |
| | (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS |
| | REQUIRED BY SEC. 1207.2 OF FBC 5TH EDITION (2014). |
| | |
| | NOTE: TEST SAMPLE TO MATCH ACTUAL BUILDING |
| | CONSTRUCTION. INFORMATION SUBMITTED IS FOR 8" CONCRETE |
| | SLAB WITH SUSPENDED ACOUSTICAL CEILING. THERE IS NOT |
| | SUSPENDED ACOUSTICAL CEILING IN THIS BUILDING. THE STC |
| | RATING OF 67 IS INCORRECT. THIS RATING CAN ONLY BE |
| | OBTAINED IF THERE IS AN ACOUSTICAL CEILING ON THE |
| | ASSEMBLY. |
| | |
| | C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS |
| | (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS |
| | REQUIRED BY SEC. 1207.3 OF FBC 5TH EDITION (2014). |
| | |
| | NOTE: TEST SAMPLE TO MATCH ACTUAL BUILDING |
| | CONSTRUCTION. INFORMATION SUBMITTED IS FOR 8" CONCRETE |
| | SLAB WITH SUSPENDED ACOUSTICAL CEILING. THERE IS NOT |
| | SUSPENDED ACOUSTICAL CEILING IN THIS BUILDING. THE IIC |
| | RATING OF 71 IS INCORRECT. THIS RATING CAN ONLY BE |
| | OBTAINED IF THERE IS AN ACOUSTICAL CEILING ON THE |
| | ASSEMBLY. |
| | |
| | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS AND |
| | CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC. |
| | 109.3 CITY AMENDMENTS. NOTE: PROVIDE COPY OF SIGNED |
| | CONTRACT FOR ALL SCOPE OF WORK TO BE DONE. AND PROVIDE |
| | TOTAL SQUARE FOOTAGE OF AREAS TO HAVE LAMINATED |
| | FLOORING. |
| | |
| | 3- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713 F.S. |
| | |
| | 4- PERMIT APPLICATION NEEDS NOTARIZED SIGNATURE OF THE |
| | OWNER AND THE CONTRACTOR. |
| | |