2015-07-23 14:16:371ST REVIEW: FBC 2014 MECHANICAL
  
 1) THE CITY OF WEST PALM BEACH BUILDING DIVISION
 REQUIRES FIRE SUPPRESSION PLANS TO BE SUBMITTED WITH
 KITCHEN GREASE HOOD PLANS. PLEASE SUBMIT THE PLANS AND
 SPECIFICATIONS, AND SUB-PERMIT APPLICATION.
 2) THE HOOD SECTION DRAWING ON SHEET 1 INDICATES GAS
 APPLIANCES: PROVIDE A GAS PIPING PLAN, A GAS ISOMETRIC
 DRAWING, AND SUBMIT MANUFACTURER'S SPECIFICATIONS FOR
 THE GAS-FIRED APPLIANCES.
 3) INDICATE HOW COMBUSTION AIR IS BEING PROVIDED TO THE
 GAS APPLIANCES- REFER TO SECTION 304 FBC-14 FUEL GAS.
 PLEASE INCLUDE CALCULATIONS TO VERIFY COMPLIANCE WITH
 WHICHEVER METHOD IS CHOSEN.
 4) PROVIDE A DIMENSIONED FRONT SECTION VIEW OF THE HOOD
 INDICATING THE MINIMUM 6" HOOD OVERHANG OF THE
 APPLIANCES ON ALL OPEN SIDES OF THE HOOD, AND THE
 MAXIMUM 4' DISTANCE BETWEEN THE FRONT LOWER LIP OF THE
 HOOD AND THE COOKING SURFACES OF THE APPLIANCES.
 5) THE PLAN INDICATES A 3" CLEARANCE BETWEEN THE BACK
 OF THE HOOD AND THE EXISTING WALL- REFER TO SECTION
 507.9 (EXCEPTION) AND VERIFY THAT THE WALL IS OF
 NON-COMBUSTIBLE CONSTRUCTION, AND THE STAINLESS STEEL
 WALL PANELS ARE EXTENDING NOT LESS THAN 18" IN ALL
 DIRECTIONS OF THE HOOD.
 6) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE THERMAL
 CERAMICS GREASE DUCT WRAP.
 7) SHOW THE LOCATIONS OF REQUIRED CLEANOUTS ON THE TWO
 GREASE DUCTS AND PROVIDE DETAILS FOR INSTALLATION-
 REFER TO SECTION 506.3.8 ITEMS 1-8 FBC-14 MECHANICAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719