2015-08-18 14:06:211ST REVIEW: FBC 2014 5TH ED.
  
 REVISE THE CODE REFERENCE CITED ON SHEET FP AS IT IS
 INCORRECT. THE APPLICABLE CODE IS THE FBC 5TH EDITION
 EXISTING BUILDING VOLUME.
  
 PLEASE NOTE THE WINDOWS HAVE BEEN PERMITTED UNDER
 SEPARATE PERMIT. NO ADDITIONAL REVIEW FOR WINDOWS WILL
 BE CONDUCTED.
  
 PROVIDE MORE INFORMATION OR MANUFACTURER?S INFORMATION
 ON THE CAST STONE FIREPLACE. WILL IT BE INCORPORATED
 INTO THE CHIMNEY TO REMAIN? IF SO, PROVIDE DETAIL
 REVIEWED BY THE ARCHITECT CONSISTENT WITH THE
 MANUFACTURER?S INSTALLATION REQUIREMENTS.
  
 AS FOR THE CHIMNEY, NOTES ARE PROVIDED IN THE CHIMNEY
 SUPPORT DETAIL AS FOLLOWS: #6 DOWELS @ 4" O.C.; 4" X6"X
 .25 "X 3.5' L; I DO NOT UNDERSTAND WHAT THIS IS AND IF
 IT IS INTENDED TO SUPPORT THE CHIMNEY OR IF IT IS AN
 ELEVATED SLAB W/ UNEQUAL ANGLES CHIMNEY? IF STEEL
 ANGLES, IS THERE A WELD?
  
 PROVIDE DETAIL, PERHAPS BY THE STEEL FABRICATOR, AND
 REVIEWED BY THE ARCHITECT AS TO ALL STEEL CONNECTIONS
 SUCH AS COLUMN TO FLOOR, COLUMN TO BEAM, BEAM TO BEAM,
 & BEAM TO CONCRETE BEAM/BEARING PLATES.
  
 THERE IS A SINGLE 2X4 TOP PLATE OVER A STEEL BEAM TO BE
 CONNECTED BY STAGGERED THROUGH BOLTS. WILL THIS ALLOW
 FOR 5/8" EDGE DISTANCE CONSISTENT WITH FBCR602 ?
 PROVIDE A DETAIL. THE SINGLE TOP PLATE IS PROPOSED TO
 BE CONNECTED TO EXISTING ROOF FRAMING MEMBERS WITH A
 SIMPSON H10. THIS CONNECTOR IS DESIGNED FOR CONNECTION
 TO A DOUBLE, NOT A SINGLE TOP PLATE. PROVIDE AN
 ALTERNATE CONNECTOR.
  
 PROVIDE AN ATTACHMENT SCHEDULE FOR THE DENS GLASS TO
 THE WOOD FRAMING. PROVIDE ADDITIONAL FRAMING DETAILS
 FOR STUDS TO TOP & BOTTOM PLATES AND SPECIFY
 CONNECTORS. PROVIDE THE THICKNESS OF STUCCO.
  
 BASED ON THE FORGOING COMMENTS, A FULL REVIEW CANNOT BE
 COMPLETED AT THIS TIME. ADDITIONAL COMENTS MAY ARISE
 UPON SECOND REVIEW.
  
 AN ENERGY SUBMITTAL MAY BE REQUIRED UNLESS THE
 STRUCTURE IS EXEMPT PER FBCE 101.4.2, HISTORIC
 BUILDINGS
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  