| 2015-09-03 17:30:26 | 1ST REVIEW: FBC 2014 5TH ED. |
| | |
| | THE CODE REFERENCES LISTED ON THE PLAN ARE OUT OF DATE. |
| | PLEASE SPECIFY THE APPROPRIATE CODE IN EFFECT AND |
| | INDICATE THE LEVEL OF ALTERATION OR THAT THE WORK IS A |
| | CHANGE OF OCCUPANCY. REVIEW OF CITY RECORDS INDICATES |
| | THIS IS A CHANGE OF OCCUPANCY FROM STORAGE TO |
| | RESIDENTIAL PER DEFINITIONIN CHAPTER 2 OF THE |
| | FBC-EXISTING BUILDING VOLUME 5TH EDITION. |
| | |
| | APPARENTLY CHANGES WERE MADE TO THE ORIGINAL PLAN AS A |
| | FUNCTION OF THE HISTORIC REVIEW AS TO RETAINING THE |
| | CARRIAGE DOORS. THE CHANGES, ALONG WITH THE ASSOCIATED |
| | PRODUCT APPROVALS FOR THE WINDOWS AND DOORS MUST BE |
| | REVIEWED BY THE DESIGNER OF RECORD. STEPHEN GAYDOSH. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, WINDOW, AND DOOR SUBMITTALS. |
| | |
| | INDICATE IF THE BUILDING IS EXEMPT FROM THE |
| | REQUIREMENTS OF THE FBC ENERGY CONSERVATION. IS THE |
| | BUILDING TO BE CONDITIONED SPACE? IF NOT, PROVIDE |
| | EITHER: |
| | |
| | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 |
| | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO |
| | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. |
| | |
| | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. |
| | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 |
| | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE |
| | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE |
| | COMPLIANCE BY SECTION 405. |
| | |
| | R303.9 REQUIRED HEATING. |
| | WHEN THE WINTER DESIGN TEMPERATURE IN TABLE R301.2(1) |
| | IS BELOW 60?F (16?C), EVERY DWELLING UNIT SHALL BE |
| | PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING |
| | A MINIMUM ROOM TEMPERATURE OF 68?F (20?C) AT A POINT 3 |
| | FEET (914 MM) ABOVE THE FLOOR AND 2 FEET (610 MM) FROM |
| | EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN |
| | TEMPERATURE. THE INSTALLATION OF ONE OR MORE PORTABLE |
| | SPACE HEATERS SHALL NOT BE USED TO ACHIEVE COMPLIANCE |
| | WITH THIS SECTION. |
| | |
| | |
| | STEVEN KENNEDY, CBO |
| | CHIEF PLANS EXAMINER |
| | (561) 805-6710 |