| 2015-07-31 17:51:57 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, |
| | SIZES, WINDOW TYPE, ROOM DESIGNATIONS. |
| | |
| | 2. FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN |
| | HEIGHT, NOTE EXISTING CONDITIONS (TYPE OF WINDOW) AND |
| | OPENING SIZE FOR BEDROOMS, FBC R310, FBC EB 704.1. THE |
| | CLEAR OPENING CANNOT BE REDUCED BY MORE THAN 5%. |
| | |
| | TO PROVIDE FURTHER CLARIFICATION REGARDING INFORMATION |
| | NEEDED FOR BEDROOM WINDOWS WHICH ARE LESS THAN 51" IN |
| | HEIGHT: |
| | |
| | STATE WHAT TYPE OF WINDOW IS THERE NOW IN THE BEDROOMS |
| | - AWNING, CASEMENT, SINGLE HUNG? |
| | |
| | STATE WHAT THE EXISTING CLEAR OPENING DIMENSIONS ARE. |
| | CLEAR OPENING IS THE OPENING WHICH EXISTS WHEN THE |
| | WINDOW IS FULLY OPEN. |
| | |
| | STATE WHAT THE PROPOSED CLEAR OPENING DIMENSIONS ARE. |
| | THIS CAN BE OBTAINED FROM THE MANUFACTURER. |
| | |
| | 3. IMPACT PROTECTION REQUIRED, FBC 1609.1.2. AS THIS IS |
| | A COMMERCIAL BUILDING, ADDITIONAL INFORMATION WILL BE |
| | REQUIRED IF REMOVABLE IMPACT PROTECTION IS PROPOSED: |
| | |
| | PRODUCT APPROVAL |
| | |
| | INSTALLATION SCHEDULE: HTTP://WPB.ORG/DEVELOPMENT/WP-CO |
| | NTENT/UPLOADS/SITES/33/2013/09/SCHEDULE_FOR_INSTALLATIO |
| | N.PDF |
| | |
| | PLAN FOR INSTALLATION - WHERE WILL THEY BE STORED? WHO |
| | WILL INSTALL THE IMPACT PROTECTION? WHERE DOES THAT |
| | INDIVIDUAL RESIDE? WHO WILL DO THE INSTALLATION IF THAT |
| | INDIVIDUAL IS UNAVAILABLE? IF THIS IS ON THE SECOND |
| | FLOOR, HOW WILL THE SECOND FLOOR BE ACCESSED? SEE ITEM |
| | 14: |
| | |
| | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ |
| | 2013/09/WIND-BORNE_DEBRIS_IMPLEMETATION.PDF |
| | |
| | |
| | |