| Date |
Text |
| 2015-10-02 07:14:09 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15070192 |
| | ADD: 2070 PALM BEACH LAKES / CHICK-FIL-E |
| | CONT: TBD (TO BE DETERMINED) |
| | TEL: (?????????????????? NOT PROVIDED ON APPLICATION |
| | E-MAIL:???????????????? NOT PROVIDED ON APPLICATION |
| | |
| | 2014 FLORIDA BUILDING CODE W |
| | * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. OCT. 02/ 2015 |
| | ACTION: DENIED |
| | |
| | ) NOTICE!!!!!!!!!!! CHAPTER 553.80(2)(B) FLORIDA |
| | STATUTES STATES THAT A LOCAL GOVERNMENT SHALL IMPOSE A |
| | FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE |
| | REJECTED (3) OR MORE TIMES FOR REPEATED FAILURE TO |
| | CORRECT A CODE VIOLATION. |
| | |
| | |
| | 1) PREVIOUS COMMENT # 6. A TRANSMITTAL LETTER LISTING |
| | THE ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION |
| | OF THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | |
| | 2) PROVISO: PLEASE BE AWARE IF THERE IS WORK BEING |
| | COMPLETED ON EITHER THE A/C CONDENSOR STAND OR THE |
| | EQUIPMENT ITSELF THAT IS WITHIN 10 FT. OF THE PARAPET |
| | WALL, IF THE PARAPET WALL IS NOT 42 INCHES TALL THEN |
| | COMPLIANCE WITH 2014 FBC-B 1013.6 WOULD BE REQUIRED. |
| | |
| | 3) 2ND REQUEST, HIGHLIGHT ON TECHNICAL SHEET, UNIT |
| | SIZE, DECK TYPE & AMOUNT OF FASTENERS PER SIDE. SHEET |
| | A-1.7 ALSO SHOWS A NEW ROOF TOP EXHAUST FAN AND CURB. |
| | PLEASE PROVIDE PRODUCT APPROVALS FOR BOTH THE ROOF TOP |
| | CURB AND EXHAUST FAN. |
| | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES & FANS |
| | |
| | 4) 2ND REQUEST. 2014 FBC 107.3.4.1 PRODUCT APPROVALS. |
| | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE |
| | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 5)2ND REQUEST. PLEASE PROVIDE STRUCTURAL DETAILS OF THE |
| | NEW HOLE TO BE CUT INTO THE ROOF DECK NOT IN THE |
| | ARCHITECTURAL SHEETS NOR MECHANICAL SHEETS. . PROVIDE |
| | REINFORING OF THE NEW HOLE, IF BAR JOIST OR WOOD |
| | TRUSSES, BRACING FOR THE POINT LOAD, AS WELL AS THE |
| | ANCHORING OF THE EXHAUST FAN CURB TO THE ROOF DECK AND |
| | THE CURB TO THE BODY OF THE EXHAUST FAN. CURB TO TO BE |
| | ATTACHED TO FRAMING MEMBERS, PART OF THE MWFRS. MAIN |
| | WIND FORCE RESISTING SYSTEM. 1609.6.4.4.1. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |