| Date |
Text |
| 2015-08-12 15:36:00 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15070192 |
| | ADD: 2070 PALM BEACH LAKES / CHICK-FIL-E |
| | CONT: TBD (TO BE DETERMINED) |
| | TEL: (?????????????????? NOT PROVIDED ON APPLICATION |
| | E-MAIL:???????????????? NOT PROVIDED ON APPLICATION |
| | |
| | 2014 FLORIDA BUILDING CODE W |
| | * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: WED. AUGUST 12/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A-1.7 ROOF TOP PLAN HAS A NOTE ABOUT AVCOA |
| | ALUMINUM EQUIPMENT STAND. THE NOTE STATES THE FREEZER/ |
| | COOLER AND ICE MAKER CONDENSORS ARE TO REMAIN. IS THE |
| | EQUIPMENT STAND ITSELF BEING REPLACED? IF SO THEN |
| | PROVIDE A PRODUCT APPROVAL FOR THE STAND, IF |
| | PRE-ENGINEEERED. FLORIDA DEPARTMENT OF COMMUNITY |
| | AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF |
| | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE |
| | PRODUCT APPROVALS: (31)(G) PRE-ENGINEERED A/C STAND. |
| | SEE 2014 FBC-B TABLE 1509.6.5. |
| | |
| | 2) PLEASE BE AWARE IF THERE IS WORK BEING COMPLETED ON |
| | EITHER THE A/C CONDENSOR STAND OR THE EQUIPMENT ITSELF |
| | THAT IS WITHIN 10 FT. OF THE PARAPET WALL, IF THE |
| | PARAPET WALL IS NOT 42 INCHES TALL THEN COMPLIANCE WITH |
| | 2014 FBC-B 1013.6 WOULD BE REQUIRED. |
| | |
| | 3) SHEET A-1.7 ALSO SHOWS A NEW ROOF TOP EXHAUST FAN |
| | AND CURB. PLEASE PROVIDE PRODUCT APPROVALS FOR BOTH THE |
| | ROOF TOP CURB AND EXHAUST FAN. |
| | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) |
| | SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT |
| | WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(D) ROOFING PRODUCTS AND ASSEMBLIES & FANS |
| | (G) PRE-ENGINEERED A/C STANDS |
| | |
| | 4) 2014 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 5) PLEASE PROVIDE STRUCTURAL DETAILS OF THE NEW HOLE TO |
| | BE CUT INTO THE ROOF DECK. PROVIDE REINFORING OF THE |
| | NEW HOLE, IF BAR JOIST OR WOOD TRUSSES, BRACING FOR THE |
| | POINT LOAD, AS WELL AS THE ANCHORING OF THE EXHAUST FAN |
| | CURB TO THE ROOF DECK AND THE CURB TO THE BODY OF THE |
| | EXHAUST FAN. CURB TO TO BE ATTACHED TO FRAMING MEMBERS, |
| | PART OF THE MWFRS. MAIN WIND FORCE RESISTING SYSTEM. |
| | 1609.6.4.4.1. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |