| 2015-07-28 08:14:35 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15070097 |
| | ADD: 402 & 404 50TH ST. |
| | CONT: BMB SOLUTIONS |
| | TEL: (561)503-1415 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W |
| | * 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, RESIDENTIAL. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. JULY 28/2015 |
| | ACTION: DENIED |
| | |
| | 1) THE VALUE ASSESSED TO THE PROJECT IS EXTREMELY LOW |
| | FOR THE VALUE OF THE PROJECT. THE VALUE OF THE WINDOW |
| | REPLACEMENT ALONE IS BETWEEN $20,000.00 TO $25,000.00 |
| | FOR THE REPLACEMENT OF WINDOWS AND DOORS ALONE. SINCE |
| | THERE ARE SUB-PERMITS WITHIN THE PACKAGE THE VALUE FOR |
| | THE MEP PERMITS ARE ALSO TO BE ADDED TO THE VALUE OF |
| | THE MASTER PERMIT. NOTE THE IMPROVEMENT VALUE OF THIS |
| | PROPERTY IS $69,305.00. |
| | $69,305 X 0.30 = $ 20,791.50. |
| | |
| | PERMIT FEES/ PLAN REVIEW: |
| | W P B ADMINISTRATIVE CODE 108.2 SCHEDULE OF PERMIT |
| | FEES. ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, |
| | MECHANICAL AND PLUMBING SYSTEMS OR ALTERATIONS |
| | REQUIRING A PERMIT, A FEE FOR EACH PERMIT SHALL BE PAID |
| | AS REQUIRED, IN ACCORDANCE WITH THE SCHEDULE |
| | ESTABLISHED BY THE APPLICABLE GOVERNING AUTHORITY. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. |
| | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE |
| | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS |
| | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE |
| | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE |
| | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR |
| | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR |
| | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING |
| | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 2) THE PLANS INDICATE THEY WERE DESIGNED TO THE 2010 |
| | FBC, THE 5TH EDITION OF THE FBC WAS ADOPTED STATE WIDE |
| | JUNE 30, 2015. PLEASE UPDATE PLANS AND REQUIREMENTS |
| | INCLUDING THE WIND DESIGN. |
| | |
| | 3) UNDER THE 2014 FBC-EXISTING BUILDING 706.4 WHEN |
| | REPLACING MORE THAN 25% OF THE GLAZED AREA OF GLAZING |
| | THE WINDOWS AND DOORS NEED TO MEET THE REQUIREMENTS OF |
| | LARGE MISSILE IMPACT GLAZING OR APPROVED STORM |
| | SHUTTERS. |
| | |
| | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 5) COMPONENTS & CLADDING 2010 FBC-B 1609.1.2 PROTECTION |
| | OF OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING, |
| | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. |
| | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS. NOT REVIEWED BY THE DESIGNER OF |
| | RECORD. |
| | (B) WINDOWS & MULLIONS, MCY ENGINEERING. WAS NOT |
| | SUBMITTED WITH A FLORIDA OR MIAMI-DADE COVER SHEET. NOT |
| | REVIEWED BY THE DESIGNER OF |
| | RECORD. |
| | (E) STORM SHUTTERS (IF THE GLAZED OPENINGS DO NOT HAVE |
| | LARGE MISSILE IMPACT TESTING) |
| | |
| | 6) SHEET1.1 & 2.1 BOTH SHOW A CORNER POST WITH WINDOWS |
| | ON BOTH SIDES, PLEASE PROVIDE WHAT TYPE OF FRAMING |
| | SYSTEM THIS CORNER POST IS CONSISTED OF AND HOW DOES IT |
| | CONNECT TO THE MWFRS MAIN WIND FORCE RESISTING SYSTEM. |
| | |
| | 7) 2014 EXISTING BUILDING CODE, 707.1. MINIMUM |
| | REQUIREMENTS. ALTERATION SUBJECT TO THIS CHAPTER SHALL |
| | COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING |
| | CODE, ENERGY CONSERVATION. |
| | |
| | 2014 ENERGY CODE DEFINITIONS: RENOVATED BUILDINGS. |
| | ARESIDENTIAL BUILDING UNDERGOING ALATERATIONS THAT |
| | VARIES OR CHANGES INSULATION, HVAC SYSTEMS WATER |
| | HEATING SYSTEMS, OR EXTERIOR ENVELOPE CONDITIONS, |
| | PROVIDED THE ESTIMATE COST OF RENOVATION EXCEEDS 30 |
| | PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE. SEE |
| | COMMENT # 1, 30% OF THE APPRAISED IMPROVEMENT VALUE OF |
| | THE STRUCTURE IS $20,791.50. |
| | |
| | PLEASE REVIEW 2014 FBC-ENERGY CODE R101.4.3 ALTERATIONS |
| | AND TABLE R402.1.1 INSULATION & FENESTRATIONS |
| | REQUIREMENTS BY COMPONENT. NOTE FOR ZONE # 1 THE |
| | FENESTRATION U-FACTOR OF O.65 AND GLAZED FENESTRATION |
| | SHGC OF 0.25. THE DESIGNER MAY LOOK AT THIS AS |
| | PRESCRIPTIVE OR PREFORMANCE BASED. |
| | |
| | 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |