| 2015-07-24 15:43:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | COMMENTS FROM PREVIOUS REVIEW: | | | | | | 1. WIND DESIGN CRITERIA FBC 1609 ARE LACKING FROM THE | | | PLAN, PLEASE REVISE. | | | | | | WIND DESIGN CRITERIA FOR THE NEW ELEMENTS WAS NOT | | | PROVIDED. THIS SHOULD BE 170MPH EXPOSURE C MINIMUM. | | | | | | SEE ALSO FBC 5TH EDITION EXISTING BUILDING, 301.1, NEW | | | STRUCTURAL ELEMENTS TO COMPLY WITH FBC 5TH EDITION. | | | | | | 2. PLANS SHOW THE FOOTINGS AT GRADE. SEE FBC 1809.4 AND | | | REVISE. SHOW DISTANCE FROM TOP OF FOOTING TO GRADE | | | (MINIMUM 12"). | | | | | | NOT ADDRESSED. SEE ALSO FBC 5TH EDITION EXISTING | | | BUILDING, 301.1, NEW STRUCTURAL ELEMENTS TO COMPLY WITH | | | FBC 5TH EDITION. ALTERNATE DESIGNS CAN BE CONSIDERED BY | | | THE BUILDING OFFICIAL BUT SHOULD ADDRESS SCOUR AND BE | | | PROPOSED AS AN ALTERNATIVE METHOD PER FBC 104.11. | | | | | | 3. PROVIDE A VERIFIABLE COPY OF THE CONTRACT FOR THIS | | | JOB, FBC 109. | | | | | | A CONTRACT WAS PROVIDED BUT APPEARS LOW. PROVIDE A COST | | | BREAKDOWN (STICK ESTIMATE). | | | | | | |
|