2015-08-28 08:36:08NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW
 COMMENTS.
 CODE: FBC-RESIDENTIAL -5TH EDITION(2014.
  
 1-BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.
  
 2- THE 2014 FBC TOOK EFFECT ON JUNE 30TH, 2015. PERMIT
 APPLICATION WAS SUBMITTED ON JUNE 30TH. BUILDING REVIEW
 WILL BE DONE BASED ON THE NEW CODE. PLEASE UPDATE ALL
 PLANS AND NOTES AS REQUIRED.
  
 3- FOR YOUR INFORMATION THIS PROPERTY IS LOCATED IN
 FLOOD ZONE A5. ELEVATIONS CERTIFICATES WILL BE REQUIRED
 DURING CONSTRUCTION.
  
 4- ARCHITECTURAL PLANS TITLE BLOCK IS MISSING ALL THE
 INFORMATION OF THE ARCHITECT WHO IS SIGNING AND SEALING
 THE PLANS AS REQUIRED BY FAC 61G1-16.004.
  
 5- PROVIDE SOIL TEST REPORT (2 COPIES). SEC. R401.4 OF
 2010 FBC-RESIDENTIAL-5TH EDITION (2014).
  
 6-SHEET A-1: REVISE THE RETENTION NOTE ON SOIL/DRAINAGE
 NOTES. SEE SEC. R318.5 AND SEC. R401.3.
  
 7- SHEET A5:
 A) A LANDING IS REQUIRED FROM THE EXERCISE ROOM TO THE
 COVERED LANAI AS REQUIRED BY SEC. R311.3
  
 B) PROVIDE SPECIFICATIONS FOR GARAGE DOORS LEADING TO
 THE CLUB ROOM AND TO THE FOYER SHOWING COMPLIANCE WITH
 SEC. R302.5.1. ALSO, ALL THE DOORS NEED TO BE EQUIPPED
 WITH A SELF-CLOSING DEVICE. PROVIDE SPECIFICATIONS ON
 PLANS.
  
 C) PROPERTY IS LOCATED IN FLOOD ZONE A5. PROVIDE SPECS
 FOR THE ELEVATOR PIT AND PIT FOR HYDRAULIC LIFT SHOWING
 COMPLIANCE WITH SEC. R322.
  
 D) DOOR 09 DOESN'T MATCH DOOR SCHEDULE. REVISE AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
  
 E) AREA CALCULATIONS ARE INCORRECT. THE ADDITION OF THE
 AREAS IS INCORRECT. REVISE AS REQUIRED. SEC. 107.2..1
 CITY AMENDMENTS.
  
 8- PROVIDE COMPLIANCE WITH THE ACCESSIBILITY SEC. R320.
  
 9- SHEET A6: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS
 REQUIRED BY SEC. R903.4.1.
  
 10- SHEET A7: SPECIFY OVERFLOW DRAINS OR SCUPPERS AS
 REQUIRED BY SEC. R903.4.1.
  
 11- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING
 COMPLIANCE WITH THE ROOF VENTILATION SEC. R806.
 NOTE: COORDINATE WITH-THE ENERGY CALCULATIONS.
  
 12- SHEET A10: STAIR RAILING DETAIL DOESN'T MATCH
 PLANS. REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
 NOTE: PROVIDE COMPLETE STAIRWAY AND RAILING SYSTEM
 SPECIFICATIONS, REVIEWED BY THE DESIGNER OF RECORD.
 THIS MAY BE SUBMITTED LATER AS A PROVISO PRIOR TO
 INSTALLATION.
  
 13- PROVIDE ICC EVALUATION REPORT FOR THE SPRAY
 INSULATION SPECIFIED ON PLANS. SEC. R316.
  
 14- SHEET A14: REVISE WINDOW DETAILS THAT SHOW BEVELED
 BUCK. NEED TO SHOW BUCKS THAT PROVIDE FULL SUPPORT TO
 THE WINDOW FRAME AS REQUIRED BY SEC. R612.7.2.1.
  
 15- REVISE ENERGY CALCULATIONS SUBMITTED:
 A) NEED TO USE CURRENT FORM FBC- ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 B) JURISDICTION NUMBER DOESN'T CORRESPOND TO CITY OF
 WEST PALM BEACH AND THE PERMIT OFFICE IS NOT PALM
 BEACH. ALSO, PROVIDE THE OWNER AND BUILDER INFORMATION.
 SEC. R101.5.1.1.2 OF FBC- ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 C) CONDITIONED FLOOR AREA DOESN'T MATCH PLANS. SEC.
 R101.5.1.1.2 OF FBC- ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 D) PROVIDE THE NAME OF THE INDIVIDUAL COMPLETING THE
 REPORT AS REQUIRED BY SEC. R405.4.2 OF FBC- ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 E) ROOF INFORMATION ON PAGE 3 OF 7: REVISE ROOF TYPE
 AND MATERIALS TO MATCH PLANS. PLANS SHOW MODIFIED
 BITUMEN AND METAL ROOF. SEC. R101.5.1.1.2 OF FBC-
 ENERGY CONSERVATION, 5TH EDITION (2014).
  
 F) CEILING INFORMATION ON PAGE 3 OF 7: R VALUE TO MATCH
 PLANS AND PAGE 1 OF 7. SEC. R101.5.1.1.2 OF FBC- ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 G) WINDOWS ON PAGE 4 OF 7: REVISE OVERHANG DEPTH AND
 SEPARATION TO MATCH PLANS. SEC. R101.5.1.1.2 OF FBC-
 ENERGY CONSERVATION, 5TH EDITION (2014).
  
 H ) PROVIDE WINDOWS AND DOORS MANUFACTURER'S SPECS
 SHOWING COMPLIANCE WITH THE U-FACTOR AND SHGC FACTOR
 SPECIFIED ON ITEM #7 AS REQUIRED BY SEC. R405.4.3 OF
 FBC- ENERGY CONSERVATION, 5TH EDITION (2014).
  
 16- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.002(33) FOR:
 A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. PROVIDE
 COMPLETE ENGINEERING PACKAGE FOR BUILDING OFFICIAL
 APPROVAL. CONTACT BROWN AT [email protected].
  
 B) 18'-0" OVERHEAD GARAGE DOOR THAT MEETS THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER OF RECORD. NOA
 15-0317.01 SUBMITTED DOESN'T MEET THE DESIGN PRESSURES.
  
 C) STOREFRONT SYSTEM WITH WINDOW SIZES AS SHOWN ON
 PLANS. SEE WINDOWS W02, W04 AND W05. NOA 12-1005.01
 SUBMITTED DOESN'T COVER THOSE SIZES.
  
 D) SLIDING GLASS DOOR #D10 WITH SIZE AS SHOWN ON PLANS.
 NOA 12-0130.13 SUBMITTED DOESN'T COVER THIS SIZE.
 MAXIMUM PANEL SIZE FOR A 10'-0" HIGH DOOR IS 48".
  
 E) CASEMENT WINDOW #W12 AS SHOWN ON PLANS. THERE
 WINDOWS MULLED TOGETHER.
  
 F) DOOR #D07 AS SHOWN ON PLANS. SEE SIZE AND DOOR WITH
 FIXED SIDELITES ASSEMBLY.
  
 G) STEEL PANEL WALL SYSTEM AS SHOWN ON PLANS.
  
 H) 14" EXHAUST AIR GRILLS AS SHOWN ON PLANS.
  
 I) METAL ROOF AS SHOWN ON PLANS.
  
 J) MODIFIED ROOFING FOR LOW SLOPE ROOF AS SHOWN ON
 PLANS. AND, IDENTIFY SELECTED APPROVED ASSEMBLY. AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF
 SELECTED ASSEMBLY DOESN'T MEET THE CALCULATED DESIGN
 PRESSURES.
  
 K) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 L) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS
 AND DETAILS. PROVIDE FLORIDA PRODUCT APPROVAL COVER
 PAGE AND PAGE SHOWING THE SPECIFIED CONNECTOR OR LIST
 THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO THE
 SPECIFIED CONNECTOR.
  
 17- DESIGNER OF RECORD TO APPROVE IN WRITING (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 18- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE
 FINISH COVERING OF THE SECOND FLOOR COVERED TERRACE.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 19- NOTE: PRIOR TO FABRICATION AND INSTALLATION PROVIDE
 COMPLETE ENGINEER PACKAGE FOR THE BAR JOIST AND
 CONCRETE DECK SYSTEMS, STAIRWAY , HANDRAILS AND
 GUARDRAILS APPROVED BY THE DESIGNER OF RECORD.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
 ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING.
 SUBMIT OLD COPIES FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]