| Date |
Text |
| 2015-08-26 16:31:13 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| | COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. |
| | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF |
| | THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | 2- THE FBC 5TH EDITION (2014) WENT INTO EFFECT ON JUNE |
| | 30TH OF 2015. THE PERMIT APPLICATION WAS SUBMITTED ON |
| | JUNE 30TH 2015. THEREFORE, THE CODE IN EFFECT AT TIME |
| | OF PERMIT APPLICATION IS THE 2014 CODE. NEED TO REVISE |
| | ALL PLANS AND NOTES REFERENCING THE FBC 5TH EDITION |
| | (2014). |
| | |
| | 3- DRAWINGS TITLE BLOCK MUST HAVE THE FIRM LICENSE |
| | NUMBER FOR ROY & POSEY ARCHITECTURE LANDSCAPE INTERIORS |
| | AS REQUIRED BY FAC SEC. 61G1-16.004. |
| | |
| | 4- SHEET A.03: |
| | A) MAIN HOUSE ENTRY DOOR: CLARIFY NOTE "REVERSE DOOR |
| | SWING". WAS THIS DOOR AN OUTSWING DOOR AND NOW IT'S |
| | REVERSED TO INSWING?. IF SO, PROVIDE COMPLETE DETAILS/ |
| | SPECIFICATIONS AND ENGINEERING SHOWING HOW THE DOOR |
| | COMPLIES WITH THE WIND PRESSURES OF SEC. R301 OF FBC- |
| | 5TH EDITION (2014)-RESIDENTIAL. |
| | |
| | B) WALL TYPE LEGEND AND WALL HATCHED ON THE FLOOR PLAN |
| | DON'T MATCH. SEC. 107.2.1 CITY AMENDMENTS. ALSO, WALL |
| | LEGEND IS NOT LEGIBLE. TYPE OF WALL LETTERING IS |
| | OVERLAPPING. REVISE AS REQUIRED. SEC. 107.2.1.4 CITY |
| | AMENDMENTS. |
| | |
| | 5- DESIGNER OF RECORD TO SPECIFY ROOF TILE FASTENING AS |
| | REQUIRED BY SEC. 107.2.1.2 CITY AMENDMENTS. IF USING |
| | SCREWS/NAILS, THEN SPECIFY SIZE AND NUMBER. |
| | |
| | 6- SPECIFY CARBON MONOXIDE ALARMS BY ALL SLEEPING ROOM |
| | AS REQUIRED BY SEC. R315. |
| | |
| | 7- SPECIFY TYPE AND SIZE OF EXISTING BEDROOM WINDOWS |
| | AND TYPE AND SIZE OF PROPOSED WINDOWS TO VERIFY |
| | COMPLIANCE WITH EGRESS REQUIREMENTS OF SEC. 704 OF FBC- |
| | EXISTING BUILDING -5TH EDITION (2014). |
| | NOTE: BEDROOM #2 USED TO HAVE A DOOR LEADING TO AN |
| | STAIRWAY. THIS BEDROOM MUST HAVE AT LEAST ONE EGRESS |
| | WINDOW THAT COMPLIES WITH SEC. R310. |
| | |
| | 8- SHEET A.04 AND SHEET A.05; CLEARLY SPECIFY ROOF |
| | DRAINAGE FOR ALL NEW FLAT ROOFS (CARRIAGE HOUSE AND |
| | COVERED PORCH) AS REQUIRED BY SEC. R903.4 . |
| | ALSO, SPECIFY OVERFLOW DRAINS OR SCUPPERS AS REQUIRED |
| | BY SEC. R903.4.1. |
| | |
| | 9- FRONT ENTRY STAIR DETAIL 3/A.06: RAILING TO COMPLY |
| | WITH SEC. R311.7.8. |
| | |
| | 10- SPECIFY ROOF VENTILATION FOR THE NEW CARRIAGE HOUSE |
| | AND FOR NEW FLORIDA ROOM (COVERED PORCH) DETAIL 3/A.11 |
| | AS REQUIRED BY SEC. R806. |
| | |
| | 11- TABLE R702.1(1) REQUIRES 7/8" STUCCO THICKNESS (NOT |
| | 3/4"). REVISE SPECIFICATIONS ON ALL WALL SECTIONS AND |
| | ALL DETAILS AS REQUIRED. |
| | |
| | 12- PROVIDE ENERGY CALCULATIONS FOR THE NEW CARRIAGE |
| | HOUSE AS REQUIRED BY SEC. 1106 OF FBC-EXISTING |
| | BUILDING, 5TH EDITION (2014). NOTE: PLANS AND ENERGY |
| | CALCULATIONS TO BE COORDINATED TO AVOID CONFLICTS OR |
| | DELAYS. |
| | |
| | 13- SHEET S-1: |
| | A) CODE IN EFFECT AS OF JUNE 30TH 2015 IS THE FBC-5TH |
| | EDITION (2014). REVISE PLANS AS REQUIRED. |
| | |
| | B) DETAIL 8/S-1: PROVIDE COMPLETE DETAIL THAT MATCHES |
| | EXTERIOR ELEVATIONS. PROVIDE COMPLETE DETAILS AND |
| | SPECIFICATIONS FOR THE FRAMING OF THE PARAPET WALLS. |
| | ALSO, REVISE SIZE OF ROOF TRUSSES TO MATCH: 12" OR 16" |
| | TRUSSES?. SEC. R301. |
| | |
| | C) REVISE ROOF SHEATHING SPECIFICATIONS SHOWN ON THE |
| | MAIN HOUSE COVERED PORCH ROOF FRAMING PLAN. NEED TO |
| | SPECIFY MIN. 8D RING SHANK NAILS AS REQUIRED BY SEC. |
| | R803.2.3.1 OR PROVIDE ENGINEERING ANALYSIS SHOWING THAT |
| | 10D COMMON NAILS ARE EQUIVALENT TO THE 8D RING SHANK |
| | NAILS. SEC. 107.2.1.3 CITY AMENDMENTS. NOTE: THIS |
| | APPLIES TO THE CARRIAGE HOUSE ALSO. |
| | |
| | D) PROVIDE COMPLETE DOOR AND WINDOW FRAMING DETAILS FOR |
| | ALL NEW DOORS AND WINDOWS. SPECIFY ALL FRAMING MEMBERS |
| | AND CONNECTORS. SEC. R301. |
| | |
| | E) WALL SECTIONS: SPECIFY 6" MIN. CLEARANCE FROM GRADE |
| | AS REQUIRED BY SEC. R404.1.6. |
| | NOTE: COORDINATE WITH FOOTING SIZE MF-1. |
| | |
| | F) PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR ALL |
| | COLUMNS CONNECTIONS AT TOP AND BOTTOM. SPECIFY ALL |
| | PLATES SIZES, LENGTH AND NUMBER OF ANCHORS AND ALL TOP |
| | CONNECTORS. SEC. R301. |
| | |
| | G) COVERED PORCH ROOF FRAMING PLAN: SPECIFY CONNECTORS |
| | AT THE ENDS OF ALL WOOD BEAMS AND GIRDER TRUSS SHOWN |
| | NEXT TO THE EXISTING WALL. SEC. R301. |
| | |
| | 14- SHEET S-2: |
| | A) UPDATE THE "BASIS OF DESIGN" INFORMATION. REFER TO |
| | CURRENT CODE 2014. REVISE BUILDING EXPOSURE AND THE |
| | WIND VELOCITY. SEC. R301. |
| | |
| | B) OUTRIGGER DETAIL: SPECIFY ALL FRAMING MEMBERS AND |
| | CONNECTORS. SEC. R301. |
| | |
| | C) SITE WALL DETAIL. (1)THERE ARE TWO DIFFERENT HEIGHTS |
| | SHOWN ON PLANS. REVISE AS REQUIRED TO MATCH PLANS. SEC. |
| | 107.2.1 CITY AMENDMENTS. (2)PROVIDE EMBEDMENT DEPTH OR |
| | PROVIDE GEOTECHNICAL REPORT AS SPECIFIED ON THE DETAIL. |
| | SEC. R301. (3)PROVIDE MANUFACTURER'S SPECS FOR THE |
| | SPECIFIED HELICAL CONNECTORS. |
| | |
| | D) PROVIDE ONLY THE DETAILS THAT APPLY TO THIS PROJECT |
| | TO AVOID CONFLICTS. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 15- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.002(33) FOR: |
| | A) ALL FRENCH DOORS AS SHOWN ON PLANS. NEED PRODUCT |
| | APPROVAL FOR 2014 CODE VERSION. FLORIDA PRODUCT |
| | APPROVAL FL16521 SUBMITTED IS FOR 2010 CODE VERSION. |
| | NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL LOCATION OF |
| | DOOR. FOR EXAMPLE LIVING ROOM, NEW CARRIAGE LIVING |
| | AREA, ETC. |
| | |
| | B) ALL FRENCH DOORS AS SHOWN ON PLANS. NEED PRODUCT |
| | APPROVAL FOR 2014 CODE VERSION. FLORIDA PRODUCT |
| | APPROVAL FL15916 SUBMITTED IS FOR 2010 CODE VERSION. |
| | NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL LOCATION OF |
| | DOOR. FOR EXAMPLE LIVING ROOM, NEW CARRIAGE LIVING |
| | AREA, ETC. |
| | |
| | C) ALL FIXED WINDOWS AS SHOWN ON PLANS. NEED PRODUCT |
| | APPROVAL FOR 2014 CODE VERSION. FLORIDA PRODUCT |
| | APPROVAL FL15189-R1 SUBMITTED IS FOR 2010 CODE VERSION. |
| | NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL LOCATION OF |
| | WINDOW . FOR EXAMPLE LIVING ROOM, NEW CARRIAGE LIVING |
| | AREA, ETC. |
| | |
| | D) ALL CASEMENT WINDOWS AS SHOWN ON PLANS. NEED PRODUCT |
| | APPROVAL FOR 2014 CODE VERSION. FLORIDA PRODUCT |
| | APPROVAL FL15190 SUBMITTED IS FOR 2010 CODE VERSION. |
| | NOTE: CLEARLY IDENTIFY ON PRODUCT APPROVAL LOCATION OF |
| | CASEMENT WINDOW. FOR EXAMPLE LIVING ROOM, NEW CARRIAGE |
| | LIVING AREA, ETC. |
| | |
| | E) CONCRETE TILE ADHESIVE IF SPECIFIED BY THE DESIGNER |
| | OF RECORD. SEE CONCRETE TILE NOA FOR LISTED ADHESIVES. |
| | |
| | F) SLIDING GLASS DOORS AS SHOWN ON PLANS. |
| | |
| | G) NEW STORAGE DOORS AS SHOWN ON PLANS. |
| | |
| | H) NEW CRAWL SPACE ACCESS DOOR AS SHOWN ON PLANS. |
| | |
| | I) FLAT ROOF. AND CLEARLY IDENTIFY APPROVED ASSEMBLY TO |
| | BE INSTALLED. AND PROVIDE SIGNED AND SEALED RAS 117 |
| | CALCULATIONS IF REQUIRED BY THE PRODUCT APPROVAL |
| | SUBMITTED TO MEET THE CALCULATED DESIGN PRESSURES. SEC. |
| | R301. |
| | |
| | J) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON PLANS |
| | AND ALL DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT |
| | APPROVAL COVER PAGE AND PAGE SHOWING THE SPECIFIED |
| | CONNECTOR. OR DESIGNER OF RECORD TO LIST THE FLORIDA |
| | PRODUCT APPROVAL NUMBER NEXT TO THE SPECIFIED |
| | CONNECTOR. |
| | |
| | 16- DESIGNER OF RECORD TO APPROVE IN WRITING (NOT |
| | SIGNING AND SEALING) ALL PRODUCT APPROVALS AS REQUIRED |
| | BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | NOTE: PRODUCT APPROVALS SUBMITTED HAVE A REVIEW STAMP |
| | FROM "MESA ARCHITECTURE ". THIS IS NOT THE FIRM ON THE |
| | TILTE BLOCK AND IT'S BLANK. IT WAS NOT SIGNED BY THE |
| | ARCHITECT OR ENGINEER OF RECORD EITHER. |
| | |
| | 17- CARRIAGE HOUSE: PROVIDE INFORMATION SHOWING |
| | COMPLIANCE WITH THE HEATING REQUIREMENTS OF SEC. |
| | R303.9. |
| | |
| | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ***PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. |
| | SUBMIT OLD COPIES FOR REFERENCE. |
| | |