2015-08-26 08:14:241ST REVIEW: FBC 2010 RESIDENTIAL
 PERMIT #15061348
 8/26/15
  
 1) THE SUBMITTED SOIL TESTING AND ENGINEERING REPORT
 FROM ALTERRA IS INCOMPLETE (SUBJECT: DEMUCKING
 INTERVENTION). REFER TO PARAGRAPH 2 OF THE COVER LETTER
 AND SUBMIT COPIES OF THE FEBRUARY/2015 GEOTECHNICAL
 REPORT WHICH, ACCORDING TO THE LETTER, PROVIDES
 "RECOMMENDATIONS FOR BEARING-GRADE PREPARATION" OF THE
 SOIL. THE COMPLETE REPORT SHALL INCLUDE AMONG OTHER
 THINGS, A DIMENSIONED DRAWING OF THE AREA(S) OF THE LOT
 THAT WERE DEMUCKED (WAS THE POOL INCLUDED?), THE CLEAN
 SAND FILL AND COMPACTION PROCEDURE, AND ESTABLISH THE
 LOAD BEARING VALUE OF THE SOIL- REFER TO SECTIONS
 R401.4 AND R506 FBC-10 RESIDENTIAL
 2) REFER TO SECTION R802.1.6.1 AND SUBMIT TWO COPIES OF
 THE ROOF TRUSS DESIGN DRAWINGS.
 3) REFER TO TABLE R301.2(2) AND CORRECT THE COMPONENT
 AND CLADDING WIND PRESSURES (ULTIMATE DESIGN WIND
 SPEED). PLEASE INCLUDE THE MEAN ROOF HEIGHT.
 4) SHEET S-0: PROVIDE NOTES AND DETAILS FOR
 FIREBLOCKING AND DRAFTSTOPPING- REFER TO SECTIONS
 R302.11 & R302.12.
 5) SHEET S-1: REFER TO THE SURVEY AND PROVIDE THE
 FINISH FLOOR ELEVATION ON THE DRAWING.
 6) S-1: REFER TO SECTION R506.2.3 AND INDICATE THE TYPE
 AND THICKNESS OF THE SLAB VAPOR BARRIER.
 7) S-1: REFER TO SECTION R506.2.5 AND INDICATE THE TYPE
 OF SLAB REINFORCEMENT TO BE INSTALLED. IF WIRE MESH IS
 TO BE INSTALLED PROVIDE DETAILS INDICATING THE TYPE AND
 SIZE OF WIRE, AND HOW THE WIRE WILL BE SUPPORTED AND
 LAPPED.
 8) INDICATE THE AREAS OF THE SLAB WHERE CRACK BARS WILL
 ME INSTALLED AND PROVIDE DETAILS IF APPLICABLE.
 9) S-1: & S3.: PROVIDE A DETAIL AND SYMBOL FOR THE
 RECESSED SHOWER SLABS.
 10) S-2.1: THE 8"X12" TB #2 OVER THE 18'0" GARAGE DOOR
 OPENING IS OVERSPANNED PER TABLE R611.8. PLEASE
 CORRECT.
 11) S-3.3: THE WINDOW AND DOOR BUCK ATTACHMENT DETAILS
 SHOW BEVELED BUCKS WHICH ARE NOT PERMITTED PER SECTION
 R612.10.2.1. PLEASE CORRECT.
 12) S-3.3, TYPICAL WALL SECTION: PROVIDE THE SLOPE OF
 THE GRADE AT THE FOUNDATION PER SECTION R401.3.
 13) S-3.4: PROVIDE A DETAIL FOR L-28 AS SHOWN ON SHEET
 S-2.1.
 14) A-1: INDICATE THE LOCATION OF THE REQUIRED ATTIC
 HATCH, AND PROVIDE A DETAIL FOR INSTALLATION- SECTION
 R807.1.
 15) A-1: PROVIDE ROUGH FRAMING AND INTERIOR FINISH
 DETAILS FOR THE COFFERED CEILINGS.
 16) A-1: "F" TYPE WINDOWS ARE SHOWN AT THE MASTER BATH,
 HOWEVER THEY ARE NOT INCLUDED IN THE SCHEDULE ON A7.
 PLEASE NOTE THAT THE F AND B TYPE WINDOWS SHALL HAVE
 TEMPERED GLASS -SECTION R308.4.
 17) A-1: PROVIDE A SEDCTION DETAIL FOR THE
 GARAGE/LIVING SEPARATION WALL- SECTION R302.6.
 18) A-1 & A-7: INDICATE WHICH BATHROOM DOOR IS MEETING
 THE MINIMUM 29 INCH CLEAR WIDTH OPENING REQUIRED BY
 SECTION R320.1.1.
 19) A-1 & A-7: PROVIDE A COMPLETE WINDOW SCHEDULE THAT
 INCLUDES THE TYPES OF WINDOWS TO BE INSTALLED- IMPACT
 OR NON-IMPACT, WINDOW FRAME MATERIALS, WIDTH AND
 HEIGHT, AND THICKNESSES AND EFFICIENCY RATINGS OF THE
 GLASS. EGRESS WINDOWS AND THEIR CLEAR OPENING SIZES
 SHALL BE SHOWN IN THE SCHEDULE.- REFER TO SECTION
 R310.1.
 20) A-4: COVERED PATIO- A BOND BREAK SHALL BE PROVIDED
 BETWEEN THE WATER RESISTIVE BARRIER AND THE STUCCO-
 REFER TO SECTION R703.6.3 AND CHOOSE ONE OF THE THREE
 METHODS SHOWN. PLEASE NOTE THAT HIGH RIB LATH (3/8") IS
 REQUIRED FOR CEILING INSTALLATIONS PER THE ASTM C1063
 STANDARD.
 21) A-4: PROVIDE ROUGH FRAMING AND EXTERIOR FINISH
 DETAILS FOR THE COVERED ENTRY AND OUTDOOR KITCHEN
 CEILINGS.
 22) A- 6: PROVIDE ATTIC VENTILATION CALCULATIONS IN
 ACCORDANCE WITH SECTIONS R806.1 & R806.2.
 23) E-1: CARBON MONOXIDE DETECTORS SHALL BE INSTALLED
 WITHIN 10' OF EACH BEDROOM- SECTION R315.1.
 24) PRODUCT APPROVALS REQUIRED BUT NOT INCLUDED IN THE
 SUBMITTAL PACKAGE:
 A) ROOF TILE AND INSTALLATION COMPONENTS- UNDERLAYMENT,
 FOAM ADHESIVE- IF TO BE USED.
 B) #1 FOYER DOOR.
 C) #12 MASTER BEDRM WOOD FRAME ENTRY DOOR.
 D) #17 BREAKFAST WOOD FRAME ENTRY DOOR.
 E) #20 CABANA WOOD FRAME ENTRY DOOR.
 F) #30 GARAGE METAL FRAME ENTRY DOOR.
 PLEASE NOTE IN REGARD TO THE SUBMITTAL PACKAGE: A) ALL
 SUBMITTALS FOR WINDOWS AND DOORS ARE PGT "ALUMINUM"
 WHICH IS IN CONFLICT WITH THE SCHEDULES- PLEASE
 CORRECT. B) DUPLICATE COPIES OF THE WINDOW AND DOOR
 PRODUCT APPROVALS (EXCEPT GARAGE) WERE NOT SUBMITTED.
 C) ALL PRODUCT APPROVALS OR NOA'S MUST BE REVIEWED AND
 APPROVED BY THE DESIGN PROFESSIONAL RECORD WHO SHALL
 CIRCLE, HIGHLIGHT, OR OTHERWISE MARK ALL APPLICABLE
 INSTALLATION NOTES AND DETAILS, FRAME AND GLASS TYPES,
 DESIGN PRESSURES, ANCHORS ETC.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719