Plan Review Notes
Plan Review Notes For Permit 15061338
Permit Number 15061338
Review Stop B
Sequence Number 1
Notes
Date Text
2015-07-23 14:48:19BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15061338
 ADD: 777 S. FLAGLER DRIVE SUITE # 130
 CONT: PDC DEVELOPMENT
 TEL: (561)793-5852
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. JULY 23/ 2015
 ACTION: DENIED
  
 1) THE ARCHITECTURAL SHEETS ARE SEALED BUT NOT SIGNED
 NOR DATED. PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND BEING
 FILED FOR PUBLIC RECORD SHALL HAVE THE SIGNATURE AND
 SEAL OF THE DESIGN PROFESSIONAL AFFIXED TO THE
 DOCUMENT.
 FL ADMIN CODE 61G16.003 ARCHITECTS. PLANS ARE TO BE
 SIGNED WITH A FULL SIGNATURE FROM THE ARCHITECT OF
 RECORD PER 481.221 WITH A MINIMUM OF FIRST AND LAST
 NAME AS SHOWN ON THE ARCHITECTS' LICENSE, FAC
 61G1-16.003
  
 2) SHEET A2.01 RESTROOM # 105 INDICATES SEE DETAILS
 FOUND ON SHEET A6.03 DETAIL # 4. THE PLANS INDICATE A
 DIMENSION OF 4'-10 3/4" FROM THE WALL TO THE SIDE OF
 THE STONE VANITY TOP. EVEN THOUGH THE WATER CLOSET IS
 SET AT 1'-4 3/4 " THE REQUIRED CLEARANCE AROUND THE
 WATER CLOSET IS STILL 60 INCHES MINIMUM MEASURED
 PERPENDICULAR FROM THE SIDE WALL. 2010
 FBC-ACCESSIBILITY CODE 604.3.1.
  
 3) SHEET A2.01 SHOWS THE KITCHEN AND BATHROOM AS MODELS
 FOR THE BRISTOL HIGHRISE SALES CENTER. PLEASE NOTE THE
 MODEL KITCHEN AND BATHROOMS DO NOT INDICATE THE
 REQUIRED FORWARD AND SIDE APPROACH FOR APPLIANCES AND
 FIXTURES. FAIR HOUSING CHAPTER 5.
  
 4) SHEET A2.01 THE MODEL KITCHEN SHOWS A ISLAND CABINET
 THEN 3'-6" AND THEN MICROWAVE OVENS AND FREEZER/
 REFRIGARATOR. THE REFRIGARATOR & FREEZER NORMALLY STICK
 OUT FURTHER THAN THE CABINETRY. THE PLANS SHOW A 3'-6"
 BUT THE FAIR HOUSING GUIDELINE INDICATES A MINIMUM OF
 40 INCHES EXCLUDING DOOR HANDLES. THE 40 "MUST BE
 MAINTAINED BETWEEN ISLAND AND ALL OPPOSING FEATURES.
 PAGE 7.8 FAIR HOUSING GUIDELINE.
  
 5) SHEET A2.01 PLEASE INDICATE IF THE MODEL BATHROOM IS
 MEET THE SPECIFICATIONS FOR EITHER A OR B OF THE FAIR
 HOUSING GUIDELINES, PAGE 7.34 OF GUIDELINE.
  
 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  