| 2015-07-16 17:59:38 | PLEASE NOTE THAT I, MIKE ALBARRAN, ELECTRICAL PLANS |
| | EXAMINER HAVE COMPLETED THE REVIEW OF THE ABOVE |
| | MENTIONED JOB. BELOW ARE THE COMMENTS WITH REGARDS TO |
| | THE REQUIRED CORRECTIONS. THE FOLLOWING ITEMS SHALL BE |
| | CORRECTED AND THE PLANS RESUBMITTED FOR ANOTHER REVIEW. |
| | |
| | 1. GENERAL ELECTRICAL NOTES CORRECTIONS REQUIRED: |
| | A) #7, THE INTENT OF THE WORD ?ROMEX? AS USED IN THIS |
| | NOTE IS TO IDENTIFY A TYPE OF CABLE. ROMEX IS A BRAND |
| | NAME AND NOT A TYPE OF CABLE, REFER TO CABLE TYPES |
| | ?NM?, ?NMC? OR ?NMS?. |
| | B) #23, TO REFER TO FBC-R314 & 315. R-313 REFERS TO |
| | FIRE SPRINKLERS. |
| | 2. INCLUDE A NOTE ADDRESSING THE NEC 314.27 REQUIREMENT |
| | FOR CEILING OUTLETS FOR LUMINAIRES BEING LISTED TO |
| | SUPPORT 50LBS. |
| | 3. THE FLOOR PLAN REFLECTS TWO PANELS AND A POOL PANEL. |
| | ONE ADJACENT TO THE METER SOCKET, THE OTHER IN THE |
| | KITCHEN AND THE POOL PANEL OUTSIDE OF THE GARAGE. YET |
| | YOUR ELECTRICAL RISER DIAGRAM REFLECTS ONLY A NEW PANEL |
| | AND THE EXISTING POOL PANEL. CLARIFY THIS SO THEY ALL |
| | MATCH. |
| | 4. INCLUDE SITE SPECIFIC ELECTRICAL LOAD CALCS AS |
| | INDICATED IN NEC 220.16 & NEC 220.82. |
| | 5. THE NEW AHU AND WH ARE MISSING THE REQUIRED |
| | DISCONNECTS. |
| | 6. NEC 210.52(E) REQUIRES THAT THERE BE A GFCI OUTLET |
| | IN THE FRONT OF THE RESIDENCE. IF ONE IS ALREADY THERE, |
| | INDICATE IT ON THE DRAWING AS EXISTING OTHERWISE |
| | INCLUDE IN THE NEW DRAWING. |
| | 7. THE LOCATION OF THE EXISTING ELECTRIC METER AND POOL |
| | PANEL LEAD ME TO BELIEVE THAT THERE MAY BE A CODE/LIFE |
| | SAFETY VIOLATION WITH THE SERVICE DROP ENCROACHING THE |
| | MINIMUM SEPARATION REQUIREMENTS OF THE POOL. PROVIDE A |
| | SITE PLAN SHOWING THE LOCATION OF THE UTILITY POLE, |
| | SERVICE DROP TO METER WITH RELATION TO THE POOL. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | |
| | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO |
| | CONTACT ME DIRECTLY. |
| | |