| 2015-07-20 17:13:17 | 7/20/2015 |
| | PROJECT: KITCHEN REMODEL |
| | PERMIT#: 15060935 |
| | CODE: 2008 EDITION OF THE NEC, 2010 EDITION OF THE FBC, |
| | 2010 WPB AMENDMENTS TO THE FBC, CHAPTER ONE, |
| | ADMINISTRATION, 2012 FBC SUPPLEMENTS. |
| | 1ST ELECTRICAL PLAN REVIEW |
| | ACTION: DENIED |
| | |
| | REVISE YOUR PLANS IN RESPONSE TO THE FOLLOWING REVIEW |
| | COMMENTS: |
| | |
| | 1) PROVIDE CODE COMPLIANT PLANS. THE PLANS SUBMITTED |
| | ARE NOT COMPLIANT IN MANY AREAS OF THE ELECTRICAL AND |
| | UILDING CODE. SEE THE FOLLOWING LIST OF CODE |
| | DEFICIENCIES: |
| | A. REQUIRED OUTLETS MISSING ON PENNINSULA. |
| | B. OUTLET SPACING REQUIREMENTS NOT MET. ADD REQUIRED |
| | OUTLETS TO MEET SPACING REQUIREMENTS. |
| | C. GFCI PROTECTION REQUIRED. ALL OUTLETS FOR KITCHEN |
| | COUTERTOP REQUIRE GFCI PROTECTION. |
| | D. AFCI PROTECTION REQUIRED, ALL NEW RECEPTACLES |
| | REQUIRE AFCI PROTECTION. |
| | E.TAMPER RESISTANT RECEPTACLES REQUIRED. ALL NEW |
| | RECEPTACLES SHALL BE TAMPER RESISTANT. |
| | F. SMOKE DETECTORS REQUIRED, WHEN ALTERATIONS, REPAIRS, |
| | OR ADDITIONS REQUIRING A PERMIT OCCUR, OR WHEN ONE OR |
| | MORE SLEEPING ROOMS ARE ADDED OR CREATED IN EXISTING |
| | DWELLINGS, THE INDIVIDUAL DWELLING UNIT SHALL BE |
| | EQUIPPED WITH SMOKE ALARMS LOCATED AS REQUIRED FOR NEW |
| | DWELLINGS. |
| | |
| | FOR CODE REFFERENCE PUPOSES REGARDING THE |
| | AFOREMENTIONED REVIEW DEFICIENCIES, SEE THE NATIONAL |
| | ELECTRICAL CODE SECTIONS 210.8, 210.52, 406.1 AND THE |
| | FLORIDA BUILDING CODE - RESIDENTIAL SECTIONS, 314 AND |
| | 315. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. SEE LINK: |
| | HTTP://WPB.ORG/DEVELOPMENT/WP-CONTENT/UPLOADS/SITES/33/ |
| | 2013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | ADDITIONALLY, IT IS REQUIRED TO INSERT THE CORRECTED |
| | PAGES INTO THE DENIED SUBMITTAL PACKAGE. VOID THE |
| | PREVIOUSLY REVIEWED SHEETS AND LEAVE FOR COMPARATIVE |
| | REVIEW. |
| | DAVID HAYES, ELECTRICAL PLANS EXAMINER, PX3421, |
| | 561-805-6717 OR [email protected] |
| | |