| 2015-07-08 17:40:17 | ****CORRECTIONS**** |
| | |
| | ART LANGE - BUILDING INSPECTOR |
| | 561-805-6667 [email protected] |
| | FBC R FLORIDA BUILDING CODE 201 5TH / FRC FLORIDA |
| | RESIDENTIAL CODE 2010 |
| | |
| | |
| | 1. PROVIDE SIZE, TYPE AND LOCATIONS OF ALL WINDOWS AND |
| | DOORS ON A SCHEDULE AND SHOW LOCATIONS ON THE FLOOR |
| | PLAN. |
| | |
| | 2. FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY |
| | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD. SPECIFICALLY, WINDOW, AND DOOR |
| | SUBMITTALS. |
| | |
| | 3. PROVIDE WIND DESIGN LOADS/DESIGN PRESSURES PURSUANT |
| | TO FBC-R301.2. |
| | |
| | 4. WHAT IS THE USE OF THE NEW ROOM CREATED. IF IT IS A |
| | BEDROOM AT LEAST ONE OPENING SHALL COMPLY WITH R310 FOR |
| | EMERGENCY ESCAPE AND RESCUE OPENINGS. |
| | |
| | 5. PROVIDE PLUMBING, ELECTRICAL AND GAS PLANS FOR |
| | REVIEW. PROVIDE MECHANICAL PLANS IF NEEDED. |
| | |
| | 6. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN |
| | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS |
| | SHALL BE |
| | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS |
| | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH |
| | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES |
| | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE |
| | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE |
| | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE |
| | DESIGN. (SEE ALSO SECTION 107.3.5). |
| | |
| | 7. PLEASE PROVIDE TWO SETS OF ALL DOCUMENTS SUBMITTED. |
| | |
| | 8. INSUFFICIENT INFORMATION SUBMITTED TO PROVIDE A PLAN |
| | REVIEW. |
| | |
| | |
| | |