| 2015-07-17 10:36:59 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15060749 | | | ADD: 5337 N. MILITARY TRL. | | | CONT: SOUTHEAST GENERAL CONSTRUCTION | | | TEL: (561)278-2776 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W | | | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION | | | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. | | | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JULY 17/2015 | | | ACTION: DENIED | | | | | | 1) SHEET EO1.01 THE LIGHT POLE DETAIL INDICATES THE | | | FOUNDATION SIZE STEEL REBAR SIZE AND SPACING, WHAT IS | | | NOT GIVEN IS THE ANCHOR BOLT FURNISHED BY THE POLE | | | MANUFACTURER. PLEASE PROVIDE THE MANUFACTURERS SPEC NOT | | | ONLY FOR THE ANCHOR BOLT SIZE & LENGTH, QUANITITY, WIND | | | DESIGN FOR POLE AND FOR THE LUMINERE. PLANS INDICATE A | | | EPA RATING OF 6.2 AT 170 MPH. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED TO DETERMINE CODE COMPLIANCE. | | | NOTE THIS IS A EXPOSURE C CATEGORY. | | | | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|