| Plan Review Notes For Permit 15060558 |
| Permit Number |
15060558 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-07-26 08:41:54 | 1) SUBMIT MSDS FOR REVIEW FOR THE FERRIC CHLORIDE. WPB | | | AMEND. TO FBC SEC.107.2.1. | | | 2) SUBMIT CIVIL DRAWINGS FOR THIS PORTION OF THE | | | PROJECT. WPB AMEND.TO 2010 107.2.1. | | | 3) SHT.0216-M-FER-04, DETAIL #3 REFERS TO SHT. | | | 0214-M-FER-02 BUT THERE IS NO #3 SHOWN OR INDICATED ON | | | THE PLAN. CLARIFY. | | | 4) SHT.0216-M-FER-OR, DETAIL #3 SHOWS A PIPELINE | | | LABELED "STORMWATER REMOVAL" & "PRODUCT RECOVERY". | | | SUBMIT DETAILS AS TO HOW THIS SEPARATION PROCESS IS | | | DONE AND INDICATE THE DISCHARGE/TERMINATION POINTS FOR | | | THE PRODUCT RECOVERY AND STORMWATER LINES. | | | 5) SHT.0766-M-STD-09 - DETAIL # 1542102 - THE WYE SHALL | | | BE INSTALLED IN THE DIRECTION OF FLOW. REVISE DETAIL. | | | 2010 FPC SEC. 706.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|