| 2015-06-11 17:51:58 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15060449 |
| | ADD: 107 FLAGLER PROMENADE S. |
| | CONT: STORM ROOFING |
| | TEL: ( 561) 689-0268 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE |
| | CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND |
| | DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, |
| | FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND |
| | RESISTANCE RATING THAT ARE REQUIRED TO BE |
| | INSTALLED. PRODUCT EVALUATION AND INSTALLATION SHALL |
| | INDICATE COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR |
| | THE SPECIFIC SITE. |
| | |
| | 1) THE TYPE OF UNDERLAYMENT HAS NOT BEEN IDENTIFIED. |
| | THE MIAMI-DADE NOA 12-0308.20 LIMITATION 3.4 MINIMUM |
| | UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE APPLICABLE |
| | ROOFING APPLICATION STANDARDS LISTED IN SECTION 4.1 |
| | HEREIN. |
| | |
| | 2) MIAMI-DADE NOA 12-0228.18 3M 2-COMPONENT FOAM ROOF |
| | TILE ADHESIVE AH-160 LIMITATION # 3 THE MINIMUM |
| | UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE ROOFING |
| | APPLICATION STANDARD RAS 120. |
| | |
| | 3) MIAMI-DADE NOA 12-0228.18 3M 2-COMPONENT FOAM ROOF |
| | TILE ADHESIVE AH-160 THE ADHESIVE PLACEMENT FROM TABLE |
| | # 1 HAS NOT BEEN IDENTIFIED, AS TO TILE PROFILE |
| | PLACEMENT DETAIL IF SINGLE PADDY OR TWO PADDY SYSTEM. |
| | |