Plan Review Notes
Plan Review Notes For Permit 15051140
Permit Number 15051140
Review Stop B
Sequence Number 1
Notes
Date Text
2015-06-22 07:40:29 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15051140
 ADD: 412/ 414 50 TH ST. UNITS A & B
 CONT: BMB SOLUTIONS CORP
 TEL: (561)503-1415
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JUNE 22/ 2015
 ACTION: DENIED
  
 1) THE PLANS INDICATE WORK BEING COMPLETED IN BOTH THE
 FRONT AND BACK UNITS, BUT NO ADDRESS IS GIVEN TO THE
 BACK UNITS TO BE ABLE TO IDENTIFY THEM. 2010 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION, 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION OF WORK
 BEING PREFORMED UNDER THIS PERMIT.
 2010 FBC-B 501.2 ADDRESS IDENTIFICATION.
  
 2) SHEET A1.2 DESIGGN PARAMETERS AND CODE REFERANCES
 BOTH REFERANCE THE 2010 FBC-RESIDENTIAL CODE. PLEASE
 NOTE THE RESIDENTIAL CODE IS FOR 1 & 2 FAMILY ONLY.
 THIS REVIEW IS BEING COMPLETED UNDER THE 2010
 FBC-BUILDING CODE. OCCUPANCY R2.
  
 3A) SHEET A1.1 IT APPEARS THAT THE WINDOWS AND DOORS
 ARE BEING REPLACED WITHIN 10 FEET OF THE STAIR AND
 LANDING ON BOTH THE FRONT AND REAR BUILDINGS. IT
 APPEARS THAT EACH UPPER APARTMENT IS A SINGLE MEANS OF
 EGRESS, NO ELEVATIONS PROVIDED TO VERIFY. SINGLE MEANS
 OF EGRESS WILL NEED 1 HOUR FIRE SEPARATION,COMPLY UNDER
 SECTION FBC-B 1019.2., FBC-B 1026.6 EXC. # 2 & 2007
 FBC-B COMMENTARY FIGURE 1023.6(1) PROTECTION OF
 EXTERIOR STAIRWAYS. DOORS AND WINDOWS WITHIN THE
 FOOTPRINT OF THE EXTERIOR STAIR REQUIRE 1 HOUR FIRE
 RATING AND WINDOWS AND DOORS WITHIN 10 FT. OF THE
 LANDINGS AND STAIR REQUIRE 3/4 HR. OPENING PROTECTIVES.
 SHOW THE FULL LENGTH OF THE EXTERIOR STAIR AND LANDINGS
 TO DETERMINE WHICH OPENINGS REQUIRE A 1 HOUR FIRE
 RATING AND WHICH REQUIRE 3/4 HOUR FIRE RATING.
  
 3B) NOTE WINDOWS AND DOORS THAT HAVE 3/4 HR AND OR 1
 HOUR FIRE RATING NORMALLY DO NOT HAVE LARGE MISSILE
 RESISTANT TESTING AND STORM SHUTTERS WILL NEED TO BE
 INSTALLED ON THESE OPENINGS. PLEASE PROVIDE THE
 FOLLOWING INFORMATION FOR CODE COMPLIANCE:
  
 PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.2.
  
 FL BLD CODE 2010 SECTION 107.2.5.,
 1609.1.2, 1715.8 & EXIST BUILD CODE 606.4 PROCEDURES: A
 COMPLETE INSTALLATION SCHEDULE SUMMARIZING &
 IDENTIFYING OPENING SIZES, STORY HEIGHTS, UNIT MARK
 NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM BAR REINFORCING
 REQUIREMENTS, WALL PRESSURE ZONES, SLAT TYPES, ETC.,
 SHALL BE SUBMITTED AT TIME OF PERMIT APPLICATION TO
 FACILITATE PLAN REVIEW AND PERMIT ISSUANCE
  
 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
 NOTE THE JELD-WEN DOORS NOT REVIEWEDD BY THE DESIGNER
 OF RECORD.
  
 5) PLEASE 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS & MULLIONS IDENTIFY WINDOW SIZES, GLAZING
 OPTIONS, MULLION IF REINFORCED, OPTIONS FOR ANCHORING
 AND PRESSURES.
 (E) SHUTTERS
  
 6) SHEET A.2 INDICATES NEW FLOORING BUT NO INFORMATION
 ON THE 2ND FLOOR INSULATION, PLEASE PROVIDE TESTING FOR
 THE FOLLOWING (3) CODE SECTIONS:
 6A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 6B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 6C)TYPE III-TYPE V CONSTRUCTION:
 719.2 CONCEALED INSTALLATION. INSULATING MATERIALS,
 WHERE CONCEALED AS INSTALLED IN BUILDINGS OF ANY TYPE
 OF CONSTRUCTION, SHALL HAVE A FLAME SPREAD INDEX OF NOT
 MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE
 THAN 450.
  
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  