Plan Review Notes
Plan Review Notes For Permit 15051022
Permit Number 15051022
Review Stop B
Sequence Number 2
Notes
Date Text
2015-09-21 10:54:07BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15051022
 ADD: 1517 CAMERON SAMUELS LANE
 CONT: A& G CONCRETE POOLS, INC
 TEL: ( 772)878-7752
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
  
  
 NOTICE!!!!!!!!!!!!!!!!!!!!!!!!!: CHAPTER 553.80(2)(B)
 FLORIDA STATUTES STATES THAT A LOCAL GOVERNMENT SHALL
 IMPOSE A FEE OF FOUR TIMES THE FEE FOR PLAN REVIEW, IF
 PLANS ARE REJECTED (3) OR MORE TIMES FOR REPEATED
 FAILURE TO CORRECT A CODE VIOLATION.
  
  
  
 2ND REVIEW
 DATE: MON. SEPT. 21/2015
 ACTION: DENIED
  
 1) 2ND REVIEW ONLY ONE SET OF AQUATIC ACCESS SALES
 BROCHURE WAS SUBMITTED. COMPLIANCE WITH THE 2010
 FBC-ACCESSIBILITY CODE CAN NOT BE DETERMINED PLEASE
 SHOW COMPLIANCE WITH:
 2010 FBC-ACCESSIBILITY COCE;
 1009.2.2 SEAT LOCATION
 1009.2.4 SEAT HEIGHT
 1009.2.5 SEAT WIDTH
 1009.2.6 FOOT REST AND ARMREST
 1009.2.7 OPERATION
 1009.2.8 SUBMERGED DEPTH
 1009.2.9 LIFTING CAPACITY
  
 2) 2ND REQUEST. SHEET 1 INDICATES THE USE OF (3) POOL
 HEATERS. PLEASE PROVIDE CODE COMPLIANCE WITH 2010
 FBC-ENERGY CODE 504.7.3 HEATED SWIMMING POOLS AND
 INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUIPED
 WITH A VAPOR RETARDANT COVER ON THE WATER OR AT THE
 WATER SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN
 TO REDUCE HEAT LOSS.
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  