| 2015-06-11 06:32:45 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15051008 |
| | ADD: 1801 S FLAGLER DR SUITE # 1709 |
| | CONT: ARTISAN DESIGN & CONSTRUCT |
| | TEL: (954)364-8544 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. JUNE 11/2015 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A1.01 SHOWS NEW WOOD AND TILE FLOORS BEING |
| | INSTALLED IN VARIOUS ROOMS OF THE SUITE. LEASE PROVIDE |
| | TESTING REPORTS FOR THE FLOOR INSULATION THAT COMPLIES |
| | WITH THE (3) FOLLOWINGS CODE SECTIONS: |
| | |
| | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION |
| | |
| | 1A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | 1B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND. |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. |
| | |
| | 1C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2. |
| | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| | |
| | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| | |
| | 2) BATHROOM LABELED ROOM 003 SHOWS A NEW SHOWER |
| | ENCLOSURE, PLEASE PROVIDE THE TYPE OF BACKING BOARD |
| | THAT WILL BE INSTALLED IN THE SHOWER ENCLOSURE AND |
| | CEILING ABOVE, SHOW COMPLIANCE WITH 2010 FBC-B 2509.2 |
| | BASE FOR TILE & 2509.3 LIMITATIONS. |
| | |
| | 3) SHEET A1.01 NOTE # 8 INDICATES NEW SOFFITS, PLEASE |
| | PROVIDE A DETAIL SHOWING THE FRAMING TYPE & SIZE, |
| | SPACING, ATTACHMENT TO WALL & DECK ABOVE, AND THE TYPE |
| | OF FINISH MATERIAL AND THICKNESS. |
| | 107.3.5.1.1 MINIMUM PLAN REVIEW CRITERIA FORCOMMERCIAL |
| | BUILDINGS. STRUCTURAL ELEMENTS. |
| | |
| | 4) SHEET A1.01 NOTES INDICATE THE REPLACEMENT OF |
| | EXTERIOR WINDOW AND SLIDDING GLASS DOORS. SHEET A2.02 |
| | PROVIDES WIND PRESSURES BUT THERE IS NO WIND DESIGN |
| | CRITERIA TO BASE THESE PRESSURES ON? NOTE IF THIS SUITE |
| | IS LOCATED IN A ZONE 4 OR ZONE 5. |
| | |
| | WIND DESIGN CRITERIA |
| | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- |
| | CHAPTER 6 OF ASCE 7-10. |
| | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C |
| | 1609.3 WIND SPEED CONVERSION |
| | |
| | |
| | 4.1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN |
| | ACCORDANCE WITH ASCE 7-10 |
| | |
| | 4.2) AN IMPORTANCE FACTOR, ASCE 7-10. |
| | |
| | 4.3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN |
| | ACCORDANCE WITH ASCE 7-10 NOTE: HIGHRISE OF 200 FT. |
| | |
| | 4.4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * |
| | SHALL BE DETERMINED FROM ASCE 7-10. EXPOSURE D |
| | |
| | 4.5) COMPONENTS & CLADDING PRESSURES POSITIVE & |
| | NEGATIVE ASCE 7-10. |
| | |
| | 5) ON THE PRODUCT APPROVALS. PLEASE CIRCLE THE |
| | FOLLOWING INFORMATION. THE WIDTH & HEIGHT OF THE UNIT, |
| | TYPE OF GLAZING IF THERE IS OPTIONS, SILL HEIGHT OF |
| | SLIDDING GLASS DOOR UNITS, MULLIONS, RE-INFORCED OR |
| | NOT, HEIGHT AND WIDTH OF TRIBUTARY AREA, AND AMOUNT OF |
| | ANCHORS PER END PLATE AND TYPE OF ANCHORS TO BE |
| | INSTALLED. WITHOUT THIS INFORMATION A REVIEW CAN NOT |
| | TAKE PLACE. 107.2.1.3 ADDITIONAL INFORMATION IS |
| | REQUIRED TO DETERMINE CODE COMPLIANCE. |
| | |
| | 6) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS |
| | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC.. |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |