| Date |
Text |
| 2015-06-10 10:38:49 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6724 |
| | |
| | 1. PROVIDE INFORMATION REGARDING THE PROPOSED SURFACING |
| | UNDER THE EQUIPMENT, FBC 443.2.2 (WOOD CHIPS, SAND, |
| | ETC.). |
| | |
| | 2. PLAY AREA TO BE SAFE PER FBC 443.2.2. THE PLAN |
| | PROVIDED STATES THAT "THE STRUCTURE DOES NOT FIT IN THE |
| | INTENDED SITE." IT APPEARS THAT THE SAFE SLIDE ZONE |
| | WHICH THE MANUFACTURER HAS DETERMINED TO BE 6' AT THE |
| | BASE OF THE SLIDES ARE NOT MET FOR TWO OF THE SLIDES. |
| | REVISE PLAN TO SHOW COMPLIANCE WITH THE MANUFACTURER'S |
| | RECOMMENDATION OR PROVIDE OTHER DOCUMENTATION TO |
| | JUSTIFY THE REDUCED SLIDE ZONE. |
| | |
| | 3. REVISE SITE PLAN TO STATE WHETHER THIS IS THE ONLY |
| | PLAY AREA, OR IF THERE ARE OTHERS AT THIS LOCATION. |
| | |
| | 4. THE PLAN IS TO INCLUDE THE PRINTED NAME AND |
| | SIGNATURE OF THE INDIVIDUAL TAKING RESPONSIBILITY FOR |
| | THE DESIGN, FBC 107. |
| | |
| | 5. IT IS DIFFICULT TO DETERMINE COMPLIANCE WITH FBC |
| | 2010 ACCESSIBILITY TABLE 240.2.1.2. SOME NUMBERS WERE |
| | PROVIDED AT THE TOP RIGHT OF THE PAGES, FOR INSTANCE: |
| | "ELEVATED 8, ACCESSIBLE 8/4, GROUND 3/3" BUT IT IS NOT |
| | CLEAR WHAT SOME OF THE NUMBERS REPRESENT. FOR EXAMPLE, |
| | "ACCESSIBLE 8/4". 8 TOTAL, FOUR ACCESSIBLE? GROUND OR |
| | ELEVATED? |
| | |
| | PLEASE PROVIDE INFORMATION IN A FORMAT WHICH SHOWS |
| | COMPLIANCE. A CHART IS RECOMMENDED - ACTIVITY TYPE, |
| | ELEVATED OR GROUND, ACCESSIBLE OR NOT. YOU MAY FIND THE |
| | FOLLOWING DOCUMENT HELPFUL, IN PARTICULAR PAGE 17: |
| | |
| | HTTPS://WWW.ACCESS-BOARD.GOV/ATTACHMENTS/ARTICLE/1369/P |
| | LAY-GUIDE.PDF |
| | |
| | 6. VALUE IS TO INCLUDE LABOR, MATERIALS, OVERHEAD, |
| | PROFIT, ENGINEERING, FBC 109. THE CONTRACT PROVIDED |
| | DOES NOT INCLUDE INSTALLATION OR THE SURFACING, FBC |
| | 109. PLEASE REVISE VALUE TO INCLUDE ALL ITEMS. |
| | |