| Date |
Text |
| 2015-05-20 14:41:13 | BUILDING PLAN REVIEW |
| | W. P. B. REVISION: 15050066 |
| | W. P. B. PERMIT: 14090028 |
| | ADD: 525 S. FLAGLER DR. 5TH FL COMMON AREA |
| | CONT:URBAN BUILDING CONCEPTS |
| | TEL: ( 561)301-9506 |
| | E-MAIL: |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | NOTE THIS BUILDING IS BUILT PRE- 3/13/1991 NOT COVERED |
| | BY FAIR HOUSING. |
| | |
| | |
| | 1) THE NEW DOORSINTO THE SAUNA AND KITCHEN AS INDICATED |
| | ON SHEET SHEET A1-1 AS DOOR TYPE # 1. SHEET A1-2 |
| | INDICATES THESE DOORS AS 2 FT 8 INCH DOORS. THEY DO NOT |
| | THE DOOR SIZE REQUIREMENTS FOUND IN FBC-B 1008.1.1 FOR |
| | MEANS OF EGRESS. A MINIMUM OF 32 INCH CLEAR, THE |
| | MINIMUM WIDTH FOR A SWING DOOR IS A 2 FT 10 INCHES. |
| | |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |