2015-04-22 10:44:451) COPPER TUBING UTILIZED FOR GAS INSTALLATION SHALL
 COMPLY WITH STANDARD TYPE "K" OR "L" OF ASTM B 88 OR
 ASTM B 280 PER THE 2010 FBCR SEC. G2414.5.2. INDICATE
 ON THE PLAN THE TYPE OF COPPER BEING INSTALLED.
 2) COPPER TUBING SHALL NOT BE USED IF THE GAS
 CONCENTRATION CONTAINS MORE THAN AN AVERAGE OF 0.3
 GRAINS OF HYDROGEN SULFIDE PER 100 STANDARD CUBIC FEET
 OF GAS PER THE 2010 FBCR SEC.G2414.5.2. DOCUMENTATION
 FROM THE GAS PURVEYOR AS TO THE AMOUNT OF HYDROGEN
 SULFIDE IN THE GAS WILL BE REQUIRED TO ALLOW THE USE OF
 COPPE TUBING FOR THIS INSTALLATION.
  