| Plan Review Notes For Permit 15040554 |
| Permit Number |
15040554 |
|
| Review Stop |
FIRE |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2015-10-28 11:03:49 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | 1. SHEET A 2.00 & 2.01 INDICATES A DOOR SWING THAT | | | SWINGS AGAINST THE PATH OF EGRESS. | | | PER SECTION NFPA 101, DOOR SWING DIRECTION, 7.2.1.4.2, | | | DOOR IS REQUIRED TO SWING IN THE DIRECTION OF EGRESS | | | TRAVEL FOR AN OCCUPANT LOAD OF 50 OR GREATER PERSONS. | | | THE LIFE SAFETY PLANS SHOWS THE REQUIRED PATH OF TRAVEL | | | THROUGH THAT DOOR. | | | | | | 2. SHEET A 2.01 INDICATES THE SINGLE MAN DOOR AS BRING | | | LOCKED AND HANDLES REMOVED. THIS IS A REQUIRED EXIT AND | | | PER SHEET A 2.00 IS INDICATED AS "EXIT B". ENSURE THIS | | | DOOR IS FULLY OPERATION AND FUNCTIONING AS A REQUIRED | | | EXIT DOOR. | | | | | | 3. SHEET E2 INDICATES NO EXIT SIGNS OVER REQUIRED EXT | | | DOORS # 2 AND EXIT B. INSTALL EXIT SIGNS OVER THESE | | | REQUIRED EXIT DOORS. | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|