| Date |
Text |
| 2015-08-14 16:57:25 | RESIDENTIAL (R3) ADDITION/ALTERATION SECOND BUILDING |
| | REVIEW CHECKLIST. |
| | CODE: 2010 FBC. |
| | |
| | NOTE: |
| | AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH |
| | COUNTY (2300 N. JOG RD.) FOR IMPACT FEES ASSESSMENT. |
| | BRING BACK COUNTY STAMPED PLANS AND COPY OF PAID |
| | RECEIPT IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF |
| | THE UNIFIED LAND DEVELOPMENT CODE. |
| | |
| | |
| | 1- PROVIDE ENERGY CALCULATIONS. SEC. 1006 OF 2010 |
| | FBC-EXISTING BUILDING. NOTE: PLEASE COORDINATE ENERGY |
| | CALCULATIONS WITH PLANS AND PRODUCT APPROVALS TO AVOID |
| | CONFLICTS AND/OR UN-NECESSARY DELAYS. |
| | |
| | RESPONSE: |
| | WRONG ENERGY CALCULATIONS FORM WAS SUBMITTED. FORM |
| | 502-2010 SUBMITTED IS FOR COMMERCIAL BUILDINGS. PROVIDE |
| | CORRECT FORM SEE SEC. 103.2.1.1 OF 2010 FBC-ENERGY |
| | CONSERVATION. PLEASE MAKE SURE ALL THE INFORMATION IS |
| | COMPLETED AND FORM IS SIGNED BY ALL REQUIRED PARTIES. |
| | ARCHITECT LISTED ON THE FORM TO SIGN AND SEAL THE |
| | DOCUMENT AS REQUIRED BY CHAPTER 481 FLORIDA STATUTE. |
| | |
| | 2- PROVIDE COMPLETE DESIGN INFORMATION: BUILDING |
| | EXPOSURE, ULTIMATE AND NOMINAL WIND SPEED. SEC. |
| | R301.2.1.3 AND SEC. R301.2.1.4 OF 2010 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | THIS BUILDING IS NO LOCATED IN EXPOSURE "B". REVISE AS |
| | REQUIRED. IT LOOKS MORE LIKE EXPOSURE "D". SEE SEC. |
| | R301.2.1.4 AND EXPOSURE "D" ON SEC. R301.2.1.4.3. |
| | REVISE AS REQUIRED OR PROVIDE COMPLETE RATIONAL |
| | ANALYSIS CALCULATIONS AS SPECIFIED ON THE EXCEPTION OF |
| | SEC. R301.2.1.4. |
| | AND REVISE ALL THE BUILDING AND COMPONENTS AND CLADDING |
| | DESIGN PRESSURES ACCORDINGLY. |
| | |
| | 3- PROPERTY IS LOCATED IN FLOOD ZONE A5. CITY FLOOD |
| | PREVENTION AND CONTROL SEC. 94-541 REQUIRES FINISH |
| | FLOOR ELEVATION TO BE 6" ABOVE THE BASE FLOOR |
| | ELEVATION. THE BASE FLOOD ELEVATION FOR FLOOD ZONE A5 |
| | IS 7'-0". PROVIDE COMPLETE INFORMATION SHOWING |
| | COMPLIANCE WITH THE FLOOD RESISTANT CONSTRUCTION AS |
| | REQUIRED BY SEC. R322 OF 2010 FBC-RESIDENTIAL. PROVIDE |
| | SURVEY SHOWING THE FINISH FLOOR ELEVATION OF EXISTING |
| | HOUSE AND GARAGE AND THE PROPOSED ADDITION. |
| | |
| | RESPONSE: |
| | (A) REVISE SURVEY SUBMITTED. THIS PROPERTY IS LOCATED |
| | IN FLOOD ZONE "A" NOT "B". |
| | |
| | (B) SURVEY SUBMITTED DOESN'T SPECIFY THE FINISHED FLOOR |
| | OF THE PROPOSED ADDITION. |
| | |
| | (C) INFORMATION SHOWN ON SURVEY AND ARCHITECTURAL PLANS |
| | DON'T MATCH. SURVEY CALLS FOR FINISH FLOOR ELEVATION OF |
| | 8.4 FOR ENTIRE HOUSE AND 6.3 FOR THE GARAGE. |
| | ARCHITECTURAL PLANS CALLS FOR 7.9 AT FAMILY ROOM AREA |
| | AND THE PROPOSED ADDITION. INFORMATION NEED TO MATCH. |
| | SURVEY NEEDS TO BE CLEAR ON ALL FINISHED FLOOR |
| | ELEVATIONS. THIS INFORMATION WILL BE REQUIRED FOR THE |
| | ELEVATION CERTIFICATES DURING CONSTRUCTION. CORRECT ALL |
| | THE INFORMATION AS REQUIRED TO MATCH. |
| | |
| | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) ALL WINDOW TYPES SHOWN ON PLANS. |
| | RESPONSE: |
| | NOT INFORMATION SUBMITTED. |
| | |
| | B) FLAT ROOF. AND CLEARLY IDENTIFY SELECTED ASSEMBLY. |
| | PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS IF THE |
| | SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES |
| | REQUIRED BY SEC. R301 OF 2010 FBC-RESIDENTIAL. |
| | RESPONSE: |
| | ARCHITECT SPECIFIED NOA ON SHEET A-1.1. NEED TO SUBMIT |
| | NOA. IDENTIFY APPROVED ASSEMBLY AND NEED THE SIGNED AND |
| | SEALED RAS 117 CALCULATIONS. |
| | |
| | C) HUGHES, SEMCO AND SIMPSON STRUCTURAL CONNECTORS |
| | SPECIFIED ON ALL DETAILS. PROVIDE ONLY THE FLORIDA |
| | PRODUCT APPROVAL COVER PAGE AND THE PAGE SHOWING THE |
| | SPECIFIED CONNECTOR. OR, LIST THE FLORIDA PRODUCT |
| | APPROVAL NUMBER NEXT TO EACH SPECIFIED CONNECTOR. |
| | RESPONSE: |
| | UNABLE TO FIND THE MIAMI-DADE NOA'S LISTED ON THE |
| | DETAILS. ALSO, HUGHES TP6X SPECIFIED ON DETAIL #4 OF |
| | SHEET A-1.1 DOESN'T HAVE ANY NOA NUMBER. |
| | |
| | D) HARDIEBOARD FASCIA, SOFFIT AND SIDING SPECIFIED ON |
| | PLANS. |
| | RESPONSE: |
| | NO INFORMATION SUBMITTED. ARCHITECT SPECIFIED NOA'S ON |
| | DRAWINGS BUT NO INFORMATION WAS SUBMITTED. |
| | |
| | E) NEW INSWING DOOR SHOWN IN THE HOME OFFICE. |
| | RESPONSE: |
| | NO INFORMATION WAS SUBMITTED. |
| | |
| | 5- DESIGN PROFESSIONAL TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 6- SHEET A-1.0: SPECIFY TYPE AND SIZE OF BEDROOM #1 |
| | WINDOW TO VERIFY COMPLIANCE WITH THE EGRESS |
| | REQUIREMENTS OF SEC. 604 OF 2010 FBC-EXISTING BUILDING. |
| | NOTE: THERE WERE SOME WINDOWS ON BEDROOM #1 THAT WERE |
| | ELIMINATED. EGRESS OPENINGS WERE REDUCED. NOW, THIS |
| | WINDOW IS THE ONLY MEANS OF EGRESS FOR THIS BEDROOM. |
| | NEED COMPLIANCE WITH SEC. R310 OF 2010 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: |
| | SPECIFY SIZE AND TYPE OF EXISTING WINDOW ON PLANS. |
| | |
| | 7- PROVIDE ICC CURRENT EVALUATION REPORT FOR THE |
| | ICYNENE INSULATION SPECIFIED ON THE WALL SECTION ON |
| | SHEET A-1.1. SEC. R316 2010 FBC-RESIDENTIAL AND SEC. |
| | 103.2.2 OF 2010 FBC-ENERGY CONSERVATION. |
| | |
| | IMPORTANT: PROPERTY IS LOCATED IN FLOOD ZONE A5: |
| | ELEVATION CERTIFICATES WILL BE REQUIRED DURING |
| | CONSTRUCTION. |
| | |
| | *** PLEASE PROVIDE A RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | *** PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. |
| | SUBMIT A COPY OF ORIGINAL DRAWINGS FOR REFERENCE. |
| | |