2015-04-08 07:51:18BUILDING PROVISO:
 INSPECTORS TO VERIFY:
 1) BONDING IS STILL INTACT WITH STAIRS HANDRAIL AND
 LIGHT NITCH. 2010 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION, 110.3
 REQUIRED INSPECTIONS. 6) SWIMMING POOL INSPECTIONS.
  
 2) 424.1.2.3.1 DEPTH AND MARKINGS. DEPTH AND MARKINGS
 SHALL MEET THE FOLLOWING CRITERIA:
 (2). PERMANENT DEPTH MARKINGS FOLLOWED BY THE
 APPROPRIATE FULL OR ABBREVIATED WORDS ?FEET,? ?FT,? OR
 ?INCHES,? ?IN,? SHALL BE INSTALLED IN MINIMUM
 4-INCH-HIGH
 (102 MM) NUMBERS AND LETTERS ON A CONTRASTING
 BACKGROUND. DEPTH MARKERS SHALL INDICATE THE ACTUAL
 POOL DEPTH, WITHIN 3 INCHES (76 MM), AT NORMAL
 OPERATING
 WATER LEVEL WHEN MEASURED 3 FEET (914 M3) FROM THE POOL
 WALL.
  
 (3.) AT A MINIMUM, THE MARKINGS SHALL BE LOCATED ON
 BOTH SIDES OF THE POOL AT THE SHALLOW END, SLOPE BREAK,
 DEEP END WALL AND DEEP POINT (IF LOCATED MORE THAN FIVE
 FEET FROM THE DEEP END WALL). DEPTH MARKINGS SHALL BE
 LEGIBLE FROM INSIDE THE POOL AND ALSO FROM THE POOL
 DECK. THE MAXIMUM PERIMETER DISTANCE BETWEEN
 DEPTH MARKINGS IS 25 FEET (7620 MM).