| Date |
Text |
| 2015-04-09 07:13:07 | BUILDING PLAN REVIEW |
| | PERMIT FOUNDATION: 15040175 |
| | FOUNDATION, STEMWALL & SLAB |
| | COM-ADD. PERMIT: 14120580 |
| | ADD: 901 45TH ST./ QUANTUM HOUSE |
| | CONT: HEDRICK BROTHERS |
| | TEL: ( 561)589-8880 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. APRIL 09/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE SEE SURVEY NOTE # 5 THIS SURVEY WAS PREPARED |
| | FOR DELINEATING THE EXISTING IMPROVEMENTS IN THE |
| | VICINITY OF THE QUANTUM HOUSE, NOT FOR THE DELINEATING |
| | THE AH FLOOD ZONE FROM THE B FLOOD ZONE. PLEASE PROVIDE |
| | A SURVEY FOR THIS LOCATION DELINIATING THE AH FLOOD |
| | PLANE AREAS. THE EXISTING STRUCTURE MAY OR MAY NOT BE |
| | LOCATED IN A AH FLOOD ZONE LOOKING BETWEEN THE FIMA |
| | FLOOD MAPS AND THE COUNTY GIS, THERE IS SOME |
| | DISCREPANCY BETWEEN THE FEMA FLOOD MAP PANEL 120192- |
| | 0015-B DATED 3/01/79 IS THE CURRENT MAP. THE BASE FLOOD |
| | ELEVATION SHOWN ON THIS MAP IS 17'-0" NGVD. |
| | IF THE EXISTING BUILDING IS LOCATED IN THE AH FLOOD |
| | ZONE, THEN SUBSTANTIAL IMPROVEMENT ON THE EXISTING |
| | BUILDING THAT WILL BE ANOTHER FACTOR, SEE W.P.B. |
| | MUNI-CODE 94-611 DEFINITION FOR SUBSTANTIAL |
| | IMPROVEMENT. |
| | |
| | |
| | 2) BUILDING PROVISO: RESIDENT INSPECTOR AGREEMENT |
| | REQUIRED BEFORE PERMIT 14120580 IS ISSUED. |
| | THIS BUILDING QUALIFIES FOR THE RESIDENT INSPECTOR |
| | PROGRAM WITH AN AREA OF 20,000 SQ. FT. 2010 WEST PALM |
| | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER |
| | 1, ADMINISTRATION, 110.3.9 OTHER INSPECTIONS SERVICES. |
| | THE BUILDING OFFICIAL MAY MAKE, OR CAUSE TO BE MADE BY |
| | OTHERS, THE INSPECTIONS REQUIRED BY SECTION 109. HE/SHE |
| | MAY ACCEPT REPORTS OF INSPECTORS OF RECOGNIZED |
| | INSPECTION SERVICES, PROVIDED THAT AFTER INVESTIGATION |
| | HE/SHE IS SATISFIED AS TO THEIR QUALIFICATIONS AND |
| | RELIABILITY. A CERTIFICATE CALLED FOR BY ANY PROVISION |
| | OF THE TECHNICAL CODES SHALL NOT BE BASED ON SUCH |
| | REPORTS UNLESS THE SAME ARE IN WRITING AND CERTIFIED BY |
| | A RESPONSIBLE OFFICER OF SUCH SERVICE. THE BUILDING |
| | OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY AN INSPECTION |
| | SERVICE IN THE FOLLOWING INSTANCES: (5.) FOR BUILDINGS |
| | WITH AREA GREATER THAN 20,000 SQUARE FOOT. RESIDENT |
| | INSPECTOR FORMS WILL BE E-MAILED OUT TO THE CONTRACTOR |
| | CONTACT. |
| | 2A)FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' |
| | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE |
| | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS |
| | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE |
| | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, |
| | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES |
| | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST |
| | MEETING THE ABOVE CRITERIA. |
| | CONTACT KEN CONRAD |
| | TEL: 561-805-6666 |
| | E-MAIL: [email protected] |
| | |
| | 2B) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR |
| | HISTORY FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE |
| | SUBMITTED TO KEN CONRAD BY E-MAIL. KEN CONRAD: |
| | [email protected] |
| | |
| | 2C) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE |
| | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, THE |
| | PERMIT LIBRARIAN WILL E-MAIL YOU, THE APPROVED AND |
| | BATCH STAMPED PLANS SO YOU MAY PRINT YOUR PLANS, TWO |
| | SETS OF PLANS WILL NEED TO BE PRINTED IN COLOR, (1) FOR |
| | THE RESIDENT INSPECTOR, THE OTHER FOR THE MEP |
| | INSPECTORS. |
| | |
| | 2D) PLEASE CALL THE CITY OF WEST PALM BEACH'S AUTOMATED |
| | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR |
| | IN-PROGRESS INSPECTIONS FOR AUDITING OF JOBSITE |
| | INSPECTIONS. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | DEVELOPMENT SERVICES HOME PAGE |
| | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
| | |
| | |
| | |
| | |