| Plan Review Notes For Permit 15040129 |
| Permit Number |
15040129 |
|
| Review Stop |
R |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2015-07-15 15:28:34 | 1- MODIFIED BITUMEN FOR THE FLAT ROOF. AND CLEARLY | | | IDENTIFY APPROVED ASSEMBLY. ALSO, PROVIDE SIGNED AND | | | SEALED RAS 117 CALCULATIONS IF SELECTED ASSEMBLY | | | DOESN'T MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301 | | | OF 2010 FBC-RESIDENTIAL. | | | ***RESPONSE: FLORIDA PRODUCT APPROVAL SUBMITTED | | | FL1654-R9. NEED TO PROVIDE CURRENT FLORIDA PRODUCT | | | APPROVAL REVISION #14. THE ONE SUBMITTED REVISION R9 IS | | | NOT CURRENT. ALSO, NEED TO MARK WHICH APPROVED ASSEMBLY | | | IS GOING TO BE INSTALLED TO VERIFY DESIGN PRESSURES. | | | SIGNED AND SEALED RAS 117 CALCULATIONS WILL BE REQUIRED | | | IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES FOR ALL ROOF ZONES. | | | | | | | | | 2- SHINGLES UNDERLAYMENT FL10450-R4. OK. | | | | | | 3- SHINLES NOA 11-0919.05. OK. | | | | | | | | | |
|