| 2015-09-23 05:01:24 | 1) THERE IS A CLOUDED NOTE IN THE CENTER OF THE PLAN |
| | THAT NOTES AN S-2 OCCUPANCY WITH A TOTAL OF 143 |
| | OCCUPANTS. WHERE IS THIS NUMBER COMING FROM AND WHAT IS |
| | THE S-2 OCCUPANCY REFERRING TO, ALL THE STORAGE |
| | BUILDINGS? THIS NOTE IS EXTREMELY VAGUE AS TO WHAT & |
| | WHERE IT APPLIES.CLARIFY. |
| | 2) THE OCCUPANT LOAD FOR STORAGE BUILDING #5 IS SHOWN |
| | AS 67 & 69 OCCUPANTS. WHICH IS IT? CLARIFY. |
| | 3) THE REQUIRED SANITARY FACILITIES SHALL BE EVALUATED |
| | FOR EACH BUILDING, NOT ADDED TOGETHER AS IT APPEARS IS |
| | BEING ATTEMPTED FOR THE STORAGE OCCUPANCIES. CLARIFY. |
| | 4) THE DRINKING FOUNTAINS AND THE ACCESSIBLE RESTROOMS |
| | SHALL BE ON AN ACCESSIBLE ROUTE. THE PLANS DO NOT |
| | CLEARLY SHOW THIS. THE ACCESSIBLE ROUTE SHALL COMPLY |
| | WITH THE FBC-ACCESSIBILITY SECS.206.1, 206.2.2, |
| | 206.4,302,303, 402.2, 403. |
| | 5) PLEASE PLACE THE ADDRESS OF THE BUILDINGS ON THE |
| | PLANS.WPB AMEND. TO FBC SEC.107.2.1. |
| | |
| | THE FOLLOWING INFORMATION IS PROVIDED IN THE EVENT THAT |
| | SANITARY FACILITIES ARE ADDED TO ANY OF THE BUILDINGS |
| | AT A LATER DATE. |
| | |
| | BLDG. #1 - BUSINESS OCCUPANCY - 49 OCCUPANTS -PER TABLE |
| | 403.1 - |
| | DRINKING FOUNTAIN- 2 REQUIRED PER TABLE 403.1 FOOTNOTE |
| | (E) & FBC-ACCESSIBILITY SEC.211.2. |
| | MALES (COMPLIES) |
| | WATER CLOSET- 1 |
| | LAVATORY- 1 |
| | FEMALES (COMPLIES) |
| | WATER CLOSET- 1 |
| | LAVATORY - 1 |
| | |
| | BLDG.# 2 - STORAGE OCCUPANCY - 17 OCCUPANTS - PER TABLE |
| | 403.1 |
| | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE |
| | (E) & FBC-ACCESSIBILITY SEC.211.2. |
| | WATER CLOSETS - 1 |
| | LAVATORIES - 1 |
| | SERVICE SINK - 1 |
| | |
| | BLDG.# 3 - STORAGE OCCUPANCY - 2 OCCUPANTS - PER TABLE |
| | 403.1 |
| | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE |
| | (E) & FBC-ACCESSIBILITY SEC.211.2. |
| | SERVICE SINK - 1 |
| | WATER CLOSET - 1 |
| | LAVATORY - 1 |
| | |
| | BLDG.# 4 - STORAGE OCCUPANCY - 8 OCCCUPANTS - PER TABLE |
| | 403.1 |
| | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE |
| | (E) & FBC-ACCESSIBILITY SEC.211.2. |
| | SERVICE SINK - 1 |
| | WATER CLOSET - 1 |
| | LAVATORY - 1 |
| | |
| | BLDG.# 5 - STORAGE OCCUPANCY - 67 OCCCUPANTS - PER |
| | TABLE 403.1 |
| | DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE |
| | (E) & FBC-ACCESSIBILITY SEC.211.2. |
| | SERVICE SINK - 1 |
| | WATER CLOSET - 1 |
| | LAVATORY - 1 |
| | |
| | |
| | I SUGGEST CONTACTING ME TO SET UP AN APPOINTMENT TO |
| | DISCUSS THESE COMMENTS. |
| | |
| | PLUMBING PLAN REVIEW |
| | TIM LARGE |
| | CHIEF PLUMBING INSPECTOR |
| | 561-805-6692 |
| | [email protected] |
| | |