Notes
Date Text
2015-08-24 06:57:331) SUBMIT INFORMATION AS TO THE NUMBER AND TYPE OF
 SANITARY FACILITIES THAT ARE CURRENTLY LOCATED IN EACH
 BUILDING AND THE NUMBER OF TOILET ROOMS IN EACH
 FACILITY.THIS HAS NOT BEEN DONE IN COMPLIANCE WITH THE
 FBC-PLUMBING TABLE 403.1.
 BLDG. #1 - BUSINESS OCCUPANCY - 49 OCCUPANTS -PER TABLE
 403.1 -
 DRINKING FOUNTAIN- 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 MALES
 WATER CLOSET- 1
 LAVATORY- 1
 FEMALES
 WATER CLOSET- 1
 LAVATORY - 1
  
 BLDG.# 2 - STORAGE OCCUPANCY - 17 OCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 WATER CLOSETS - 1
 LAVATORIES - 1
 SERVICE SINK - 1
  
 BLDG.# 3 - STORAGE OCCUPANCY - 2 OCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 BLDG.# 4 - STORAGE OCCUPANCY - 8 OCCCUPANTS - PER TABLE
 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 BLDG.# 5 - STORAGE OCCUPANCY - 67 OCCCUPANTS - PER
 TABLE 403.1
 DRINKING FOUNTAIN - 2 REQUIRED PER TABLE 403.1 FOOTNOTE
 (E) & FBC-ACCESSIBILITY SEC.211.2.
 SERVICE SINK - 1
 WATER CLOSET - 1
 LAVATORY - 1
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692