| 2015-04-24 06:36:07 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 15040122 |
| | ADD: 525 S. FLAGLER DR. SUITE # 29A/B |
| | CONT: R & D CONSTRUCTORS |
| | TEL: (561)889-1751 |
| | E-MAIL: [email protected] |
| | |
| | 2010 FLORIDA BUILDING CODE W |
| | * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA |
| | BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION |
| | 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013. |
| | |
| | 2010 EXISTING BUILDING CODE LEVEL II 701.3 |
| | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, |
| | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS |
| | OF THE FLORIDA BUILDING CODE, BUILDING. |
| | |
| | IMPORTANT NOTICE: EFFECTIVE MARCH 30, 2015 |
| | ALL PERMIT APPLICATION PLAN REVIEWS WILL BE PERFORMED |
| | ELECTRONICALLY |
| | UPON APPLICATION AND FEE PAYMENT DESIGN DOCUMENTS |
| | SUBMISSION OPTIONS ARE AS FOLLOWS: |
| | 1 UPLOAD VIA THE PROJECT DOX PORTAL WITH DIGITAL |
| | SIGNATURES OF DESIGN PROFESSIONALS AS APPLICABLE; USE |
| | THE REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 2 INCLUDE ON A CD IF DESIGN PROFESSIONAL DIGITAL |
| | SIGNATURES ARE PROVIDED AS REQUIRED; USE THE REQUIRED |
| | NAMING CONVENTION FOR EACH DOCUMENT |
| | 3 INCLUDE ON A CD WITH ONE SET OF TRADITIONAL PAPER |
| | DESIGN DOCUMENTS SIGNED AND SEALED AS REQUIRED; USE THE |
| | REQUIRED NAMING CONVENTION FOR EACH DOCUMENT |
| | 4 ONE SET OF TRADITIONAL PAPER DESIGN DOCUMENTS SUBJECT |
| | TO ADMINISTRATIVE FEES TO DIGITIZE THE DOCUMENTS |
| | ADDITIONAL INFORMATION WILL BE PROVIDED WHEN IT BECOMES |
| | AVAILABLE. |
| | |
| | 1ST REVIEW |
| | DATE: FRI. APRIL 24/ 2015 |
| | ACTION: DENIED |
| | |
| | 1) THERE IS NO CODE ANALYSIS FOR THE PROJECT THE PLANS |
| | DO NOT DECLARE TO WHICH CODE THE PLANS WERE DEVELOPED |
| | UNDER THE 2010 FL. EXISSTING BUILDING CODE SECTION |
| | 101.5 THE DESIGN PROFESSIONAL NEEDS TO PROVIDE WHICH |
| | COMPLIANCE METHOD THE PLANS WERE DESIGNED. |
| | |
| | 2) SHEET A-101.00 DOOR SCHEDULE, DOORS D02 & D03 |
| | INDICATE THEY ARE BOTH 2'-6" DOORS. UNDER THE 2010 |
| | FBC-B THE MINIMUM SIZE SHALL BE 32 INCHES, EXCEPTION # |
| | 1 THE MINIMUM AND MAXIMUM WIDTH SHALL NOT APPLY TO DOOR |
| | OPENINGS THAT ARE NOT PART OF THE REQUIRED MEANS OF |
| | EGRESS IN GROUP R-2 AND R-3 OCCUPANCIES. |
| | THESE DOORS ARE PART OF THE MEANS OF EGRESS. |
| | |
| | MEANS OF EGRESS. A CONTINUOUS AND UNOBSTRUCTED PATH OF |
| | VERTICAL AND HORIZONTAL EGRESS TRAVEL FROM ANY OCCUPIED |
| | PORTION OF A BUILDING OR STRUCTURE TO A PUBLIC WAY. A |
| | MEANS OF EGRESS CONSISTS OF THREE SEPARATE AND DISTINCT |
| | PARTS: THE EXIT ACCESS, THE EXIT AND THE EXIT |
| | DISCHARGE. |
| | |
| | EXIT ACCESS. THAT PORTION OF A MEANS OF EGRESS SYSTEM |
| | THAT LEADS FROM ANY OCCUPIED PORTION OF A BUILDING OR |
| | STRUCTURE TO AN EXIT. |
| | |
| | EXIT ACCESS DOORWAY. A DOOR OR ACCESS POINT ALONG THE |
| | PATH OF EGRESS TRAVEL FROM AN OCCUPIED ROOM, AREA OR |
| | SPACE WHERE THE PATH OF EGRESS ENTERS AN INTERVENING |
| | ROOM, CORRIDOR, UNENCLOSED EXIT ACCESS STAIR OR |
| | UNENCLOSED EXIT ACCESS RAMP. |
| | |
| | 3) SUBMITTED IS SPECIFICATIONS TO USE QUIET CORK FLOOR |
| | SOUND INSULATION. PLEASE SUBMIT THE FOLLOWING DOCUMENTS |
| | FOR CODE COMPLIANCE: |
| | BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION |
| | |
| | 3A) FBC-B 2010 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | 3B) FBC-B 2010 1207.2 1207.2 AIR-BORNE SOUND. |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. |
| | |
| | 3C) FLAME SPREAD- FBC-B 2010 603.1.2 EXCEPTION 2. |
| | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| | |
| | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| | |
| | 703.4 NONCOMBUSTIBILITY TESTS. |
| | THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2 |
| | SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING |
| | MATERIALS AS SET FORTH IN SECTIONS 602.2, 602.3 AND |
| | 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM |
| | ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME SPREAD |
| | CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A |
| | MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE |
| | BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN |
| | INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE |
| | LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF |
| | AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS. |
| | |
| | 703.4.1 ELEMENTARY MATERIALS. |
| | MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED |
| | IN ACCORDANCE WITH ASTM E 136. |
| | |
| | 703.4.2 COMPOSITE MATERIALS. |
| | MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE |
| | MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION |
| | 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18 |
| | MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER |
| | THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR UL |
| | 723 SHALL BE ACCEPTABLE AS NONCOMBUSTIBLE MATERIALS. |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |