2015-04-30 15:31:31RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- THERE ARE TWO DIFFERENT EQUIPMENT SIZING
 CALCULATIONS SUBMITTED. ONE DONE BY KAREN OLIVER AND
 THE OTHER ONE DONE BY ASTRO AIR INC. COORDINATE ALL THE
 INFORMATION. EQUIPMENT SIZING CALCULATIONS AND A/C
 PLANS. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: CALCULATIONS DONE BY ASTRO AIR INC ARE
 INCOMPLETE. PROVIDE COMPLETE CALCULATIONS NOT JUST THE
 SUMMARY.
  
 2- KAREN OLIVER CALCULATIONS: SUBMIT THE MANUFACTURER
 AND MODEL NUMBER OF THE A/C EQUIPMENT ALONG WITH THE
 EQUIPMENT SIZING CALCULATIONS AS REQUIRED BY SEC.
 403.6.1 OF 2010 FBC-ENERGY CONSERVATION.
  
 3- EQUIPMENT LISTED ON THE MECHANICAL PLAN EXCEEDS THE
 REQUIREMENTS OF SEC. 403.6.1.1 OF 2010 FBC-ENERGY
 CONSERVATION. AND, COORDINATE WITH ITEM #1 ABOVE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
 .