| Notes |
| Date |
Text |
| 2015-11-17 15:06:53 | 1) SUBMIT COMPLETE SPECIFICATIONS/INSTALL MANUAL FOR | | | THE TANKLESS WATER HEATER. THE ONE SHEET THAT WAS | | | SUBMITTED IS INADEQUATE.WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) THE WATER CLOSETS IN THE DWELLING UNITS SHALL BE | | | LOCATED 18 INCHES FROM AN ADJACENT WALL PER THE FAIR | | | HOUSING GUIDELINES, NOT 16"-18" AS NOTED ON THE | | | PLANS.THE 18 INCHES FROM THE CENTERLINE OF THE WATER | | | CLOSET TO THE WALL IS AN ABSOLUTE MEASUREMENT AND WILL | | | ACCOMMODATE A GRAB BAR AND THE SHOULDERS OF A PERSON | | | SEATED ON THE TOILET. | | | 3) SHT.A.6.14.1. - TYPICAL UNIT #15 - THE DOOR ON THE | | | ACCESSIBLE SHOWER IN THE MASTER BATH WILL NOT ALLOW A | | | PERSON IN A WHEELCHAIR ACCESS TO THE CONTROLS AND THE | | | SHOWER DOOR ENCROACHES INTO THE REQUIRED CLEAR FLOOR | | | SPACE ADJACENT TO THE SHOWER OPENING PREVENTING ACCESS. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|