Plan Review Notes
Plan Review Notes For Permit 15031064
Permit Number 15031064
Review Stop P
Sequence Number 1
Notes
Date Text
2015-04-18 08:49:041) SHT.A-1 - GENERAL NOTES #1 - STATES THE CONSTRUCTION
 IS TO COMPLY WITH THE 2010 FBC- RESIDENTIAL. THIS
 BUILDING IS OUTSIDE THE PARAMETERS AND SHALL COMPLY
 WITH THE 2010 FBC- BUILDING. REVISE THE NOTE.
 2) SHT. A-7.1 - THE CLEAR INSIDE DIMENSIONS FOR THE
 HANDICAP SHOWER SHALL BE 36 INCHES BY 36 INCHES CLEAR.
 FAC SEC.608.2.1.
 3) THE WIDTH OF THE ACCESSIBLE BATHROOM SHALL BE A
 MINIMUM OF 85 INCHES. TO ALLOW FOR THE REQUIRED SPACING
 OF THE FIXTURES. 86 INCHES IN WIDTH ALLOWS FOR
 CONSTRUCTION TOLERANCES.
 4) SHT. A-7.2 - THE HEIGHT OF THE GRAB BARS SHALL BE
 MEASURED FROM THE FINISH FLOOR TO THE TOP OF THE
 GRIPPING SURFACE PER SEC.609.4 OF THE 2010 FAC.
 5) SHT. A-7.2 - HANDICAP STALL DETAIL - REMOVE
 REFERENCE TO THE 2007 FBC.
 6) SHOW THE WIDTH OF THE STANDARD SHOWERS ON THE PLAN.
 SHOWERS SHALL BE A MIN. OF 30 INCHES WIDE AND A MIN. OF
 900 SQUARE INCHES PER THE FPC SEC.417.4.
 7) SUBMIT A SANITARY AND WATER RISER FOR THE CHANGES TO
 THE PLUMBING SYSTEM IN HANDICAP ACCESSIBLE UNITS. WPB
 AMEND. TO 2010 FBC SEC. 107.3.5.1.3.
 8) PROVIDE AN ELARGED FLOOR PLAN OF THE BATHROOMS AND
 KITCHENS SHOWING THE REQUIRED CLEAR FLOOR SPACE AT
 APPLIANCES AND BATHROOM FIXTURES. SHOW THE DIMENSIONS
 (L X W ) OF THE CLEAR FLOOR SPACES, NOT JUST BROKEN
 LINES. SHOW THE ROOM DIMENSIONS.COMPLY W/ 2010 FL.
 ACCESSIBILITY CODE CHAPT.6 & SEC. 804.WPB AMEND. TO
 2010 FBC SEC. 107.2.1.
 9) INDICATE ON THE PLANS THE TOTAL NUMBER OF UNITS IN
 THE STRUCTURE AND THE TOTAL NUMBER TO BE REMODELED.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  