| Plan Review Notes For Permit 15031053 |
| Permit Number |
15031053 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-04-23 17:13:30 | PLEASE SEE FIRES COMMENT ABOUT CARD READERS IN | | | STAIRWELLS. 2010 FBC-B 1022.4 PENETRATIONS. | | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | | ENCLOSURE ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | | VENTILATION OR PRESSURIZATION, SPRINKLER PIPING, | | | STANDPIPES, ELECTRICAL RACEWAY FOR FIRE DEPARTMENT | | | COMMUNICATION SYSTEMS AND ELECTRICAL RACEWAY SERVING | | | THE EXIT ENCLOSURE AND TERMINATING AT A STEEL BOX NOT | | | EXCEEDING 16 SQUARE INCHES (0.010 M2). SUCH | | | PENETRATIONS SHALL BE PROTECTED IN ACCORDANCE WITH | | | SECTION 713. THERE SHALL BE NO PENETRATIONS OR | | | COMMUNICATION OPENINGS, WHETHER PROTECTED OR NOT, | | | BETWEEN ADJACENT EXIT ENCLOSURES. |
|