Plan Review Notes
Plan Review Notes For Permit 15030484
Permit Number 15030484
Review Stop B
Sequence Number 1
Notes
Date Text
2015-04-08 07:45:46****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 THE FOLLOWING ITEMS ARE RECOMMENDED CHANGES /
 CLARIFICATIONS TO THE DESIGN OF THE PROPOSED RAMP.
 CLARIFICATIONS ARE REQUIRED, CHANGES ARE NOT MANDATORY
 FOR THIS RESIDENTIAL RAMP. PLEASE CALL ME TO DISCUSS.
 ALTHOUGH THE PROPOSED RAMP IS RESIDENTIAL, VOLUNTARY
 AND NOT SUBJECT TO FBC 2010 ACCESSIBILITY, PLEASE NOTE
 THAT THE REQUIREMENTS IN FBC 2010 ACCESSIBILITY ARE
 BASED ON FEDERAL ADA AND HAVE BEEN DEVELOPED BASED ON
 THE DESIGNS MOST USABLE BY THE DISABLED WHILE NOT
 CAUSING A HAZARD TO OTHERS. IF YOU WOULD LIKE DETAILS
 PROVIDED FOR YOU (FROM FBC 2010 ACCESSIBILITY), PLEASE
 ADVISE.
  
 1. SHOW A SECTION OR ELEVATION OF PROPOSED
 CONSTRUCTION. IT APPEARS THAT THE HIGHEST POINT ON THE
 RAMP WILL BE 6" ABOVE GRADE; DETAIL IS TO PROVIDE THIS
 INFORMATION, FBC 107.
  
 2. THE DETAIL PROVIDED SHOWS A PORTION OF THE LANDING
 IN THE RAMP. IT IS NOT CLEAR HOW THE RAMP TIES INTO THE
 LANDING.
  
 3. THE HANDRAIL SHOWS A SMALL EXTENSION AT THE BOTTOM;
 SPECIFY. THE HANDRAIL SHOWS A TURN AT THE LANDING. A
 COMPLIANT DETAIL WAS PROVIDED BUT THE PLAN VIEW DOES
 NOT SHOW THE EXTENSION AT THE TOP. ASSISTANCE
 (MODIFICATION OF THE DETAIL) WILL BE PROVIDED FOR YOU
 UPON REQUEST. FBC 2010 ACCESSIBILITY 505.10.1.
  
 4. THE WRITTEN DESCRIPTION STATES THAT THERE WILL BE A
 LANDING AT THE FRONT DOOR AND THE CONCRETE RAMP WILL
 "MATCH THE LANDING," BUT THE LANDING IS SHOWN WIDER
 THAN THE RAMP, SO INTENT IS NOT CLEAR.
  
 5. SEE FBC 2010 405.9, EDGE PROTECTION; THIS IS
 REQUIRED TO PREVENT FALLING / SLIPPING OFF THE EDGE OF
 THE RAMP. ONE EXEMPTION TO THIS IS FBC 2010
 ACCESSIBILITY 405.9(3), "EDGE PROTECTION SHALL NOT BE
 REQUIRED ON THE SIDES OF RAMP LANDINGS HAVING A
 VERTICAL DROP OFF OF 1/2 INCH MAXIMUM WITHIN 10 INCHES
 HORIZONTALLY OF THE MINIMUM LANDING AREA SPECIFIED IN
 405.7." ANOTHER OPTION IS AN EXTENDED RAMP WIDTH. THIS
 IS SHOWN GRAPHICALLY IN FBC 2010 ACCESSIBILITY 405.9.
  
 6. SEE FBC 2010 ACCESSIBILITY 505.10.1 FOR HANDRAIL
 EXTENSIONS AT TOP AND BOTTOM.
  
 7. THE COMPANY NAME ON THE APPLICATION SHOULD BE
 CONSISTENT WITH THE LICENSE, FS 489.
  
  