Plan Review Notes
Plan Review Notes For Permit 15030458
Permit Number 15030458
Review Stop P
Sequence Number 1
Notes
Date Text
2015-04-27 14:04:09PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
 1) THE LANDSCAPE PLAN SHOWS THE WATER SUPPLY FOR THE
 IRRIGATION SYSTEM AS CITY WATER. THE IRRIGATION SYSTEM
 SHALL BE PROTECTED AGAINST BACKFLOW PER THE CITY'S
 CROSS CONNECTION MANUAL. CONTACT STEVEN HUNTER AT
 561-805-2240 FOR THE PROPER TYPE OF BACKFLOW DEVICE TO
 BE INSTALLED. FBC-R P2902
 2) THE WATER HEATERS IN THE GARAGES SHALL BE PROTECTED
 FROM VEHICLE IMPACT. FBC-R P2801.2
 3) SHOW THE LOCATION OF THE CONTROLLER AND RAIN SENSOR
 FOR THE IRRIGATION SYSTEM. A RAIN SENSOR IS REQUIRED ON
 THE IRRIGATION SYSTEM PER FL. STATUTE 373.62.
  