| Plan Review Notes For Permit 15030443 |
| Permit Number |
15030443 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2015-04-07 05:01:05 | 1) SUBMIT A SET OF PLANS THAT SHOWS THE ENTIRE SCOPE OF | | | PLUMBING WORK TO BE DONE. WPB AMEND. TO 2010 FBC SEC. | | | 107.2.1. | | | 2) INDICATE ON PLANS IF THE PLUMBING FIXTURES BEING | | | REPLACED ARE GOING BACK INTO THE SAME LOCATION. | | | 3) IF THERE IS ANY WORK TO BE DONE ON THE WATER PIPING, | | | WATER-HAMMER ARRESTORS SHALL BE INSTALLED WHERE QUICK | | | CLOSING VALVES ARE UTILIZED ( ICE MAKER/WATER DISPENSER | | | FROM REFRIGERATOR OR DISHWASHER). | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|