Plan Review Notes
Plan Review Notes For Permit 15030207
Permit Number 15030207
Review Stop B
Sequence Number 1
Notes
Date Text
2015-03-14 09:21:09BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15030207
 ADD: 1411 N. FLAGLER DR. SUITE 5600
 CONT: CLAY KOHLMEYER
 TEL: ( 561)694-1214
 E-MAIL: [email protected]
  
 2010 FLORIDA BUILDING CODE W
 * 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE, CHAPTER 1, ADMINISTRATION, 2010 EDITION
 2012 FBC SUPPLEMENTS ADOPTED APRIL 25/2013.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. MARCH 14/ 2015
 ACTION: BUILDING PROVISO
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES. REVISION
 REQUIRED BEFORE FRAMING INSPECTION.
  
 1) SHEET A-1.0 ENTRY ROOM DOOR INTO INFUSION ROOM #
 115. THERE IS A NEW WALL BEING INSTALLED THAT CREATES
 THE ACCESSIBILITY CODE VIOLATION.
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 THE 2010 FBC-ACCESS. CODE SECTION 404.2.4 MANEUVERING
 CLEARANCES REQUIRES 18 INCHES CLEAR SPACE ON THE LATCH
 SIDE OF THE DOOR, SEE FIGURE 404.2.4.1(A).
  
 JAMES WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561) 805-6715
 FAX: (561)805-6676
 E-MAIL: [email protected]
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  