2015-06-12 07:34:50PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC 2010
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE EXPOSURE CATEGORY ON SHEET 1 WAS NOT CHANGED
 FROM "B" TO "C". FBC-R301.2.1.4
  
 2) THE COMPONENT AND CLADDING PRESSURES WERE NOT
 CHANGED TO REFLECT THE CHANGE TO EXPOSURE "C".
 FBC-R301.2.1
  
 3) THE NEGATIVE DESIGN PRESSURE FOR THE ONE CAR GARAGE
 DOOR IS INCORRECTLY SPECIFIED AS -334.0 PSF. PLEASE
 CORRECT.
  
 4) SUBMIT TRUSS DRAWINGS FOR EXPOSURE "C" THAT HAVE
 BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD.
 FBC-R802.1.6.1 & FAC 61G15 - 31.003
  
 5) THE PRODUCT APPROVALS FOR THE CONCRETE ROOF TILE
 LISTS SEVERAL ATTACHMENT METHODS. SPECIFY THE SPECIFIC
 METHOD THAT WILL BE USED TO INSTALL THE TILE AND RESIST
 THE OVERTURN MOMENT. FBC 107.2.1 AND FBC-R905.3
  
 6) IN ORDER TO AVOID ADDITIONAL REVIEW COMMENTS, PLEASE
 REVIEW THE PRODUCT APPROVALS THAT WERE SUBMITTED TO
 VERIFY THAT THE DESIGN PRESSURES LISTED IN THE PRODUCT
 APPROVAL WILL MEET THE EXPOSURE "C" COMPONENT AND
 CLADDING PRESSURES. FBC-R301.2.1
  
 7) THE VALUE OF WORK WAS INCREASED FROM $108,780.00 TO
 $210,760.00 BASED ON ICC VALUATION DATA. FBC 109.3
  
 8) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE
 CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER
 INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN
 ADDRESSED.