| | REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE EXPOSURE CATEGORY ON SHEET 1 WAS NOT CHANGED |
| | FROM "B" TO "C". FBC-R301.2.1.4 |
| | |
| | 2) THE COMPONENT AND CLADDING PRESSURES WERE NOT |
| | CHANGED TO REFLECT THE CHANGE TO EXPOSURE "C". |
| | FBC-R301.2.1 |
| | |
| | 3) THE NEGATIVE DESIGN PRESSURE FOR THE ONE CAR GARAGE |
| | DOOR IS INCORRECTLY SPECIFIED AS -334.0 PSF. PLEASE |
| | CORRECT. |
| | |
| | 4) SUBMIT TRUSS DRAWINGS FOR EXPOSURE "C" THAT HAVE |
| | BEEN REVIEWED AND APPROVED BY THE DESIGNER OF RECORD. |
| | FBC-R802.1.6.1 & FAC 61G15 - 31.003 |
| | |
| | 5) THE PRODUCT APPROVALS FOR THE CONCRETE ROOF TILE |
| | LISTS SEVERAL ATTACHMENT METHODS. SPECIFY THE SPECIFIC |
| | METHOD THAT WILL BE USED TO INSTALL THE TILE AND RESIST |
| | THE OVERTURN MOMENT. FBC 107.2.1 AND FBC-R905.3 |
| | |
| | 6) IN ORDER TO AVOID ADDITIONAL REVIEW COMMENTS, PLEASE |
| | REVIEW THE PRODUCT APPROVALS THAT WERE SUBMITTED TO |
| | VERIFY THAT THE DESIGN PRESSURES LISTED IN THE PRODUCT |
| | APPROVAL WILL MEET THE EXPOSURE "C" COMPONENT AND |
| | CLADDING PRESSURES. FBC-R301.2.1 |
| | |
| | 7) THE VALUE OF WORK WAS INCREASED FROM $106,460.00 TO |
| | $212,875.00 BASED ON ICC VALUATION DATA. FBC 109.3 |
| | |
| | 8) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE |
| | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER |
| | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN |
| | ADDRESSED. |