| Date |
Text |
| 2015-05-13 07:37:47 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC 2010 |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY MECHANICAL |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE ENERGY FORM IS MISSING SOME OR ALL OF THE |
| | FOLLOWING INFORMATION: OWNER, BUILDER NAME, PERMIT |
| | OFFICE ( CITY OF WEST PALM BEACH ), JURISDICTION ( |
| | 604700 ). FBC 107.2.1.4 |
| | |
| | 2) THE PRODUCT APPROVAL THAT WAS SUBMITTED FOR THE |
| | FRONT DOOR IS FOR A GLAZED SINGLE FRENCH DOOR WHERE THE |
| | GLASS AREA IS EQUAL OR GREATER THAN ONE THIRD OF THE |
| | DOOR AREA. THIS DOOR IS REQUIRED TO BE INCLUDED IN THE |
| | GLAZING CALCULATION AS A TOTAL FENESTRATION. FBC ENERGY |
| | SECTION 405.5.3 |
| | |
| | 3) ON THE MECHANICAL PLANS FOR THE MADERA MODELS THE |
| | 14" RETURN TRANSFER DUCT IS TOO SMALL FOR THE MASTER |
| | BEDROOM SUITE. THERE ARE (2) 5", (1) 4" AND (1) 8" |
| | SUPPLY DUCTS ENTERING THE MASTER SUITE WITH A TOTAL |
| | CROSS SECTIONAL AREA OF 103". FBC-R M1602.4 REQUIRES |
| | THE TRANSFER DUCT TO BE 1.5 TIMES THE CROSS SECTIONAL |
| | AREA OF THE SUPPLY DUCTS ENTERING THE SUITE AND A ONE |
| | INCH UNDERCUT OF THE DOOR. |
| | |
| | 4) THE INTERNAL GAIN CALCULATION ON THE EQUIPMENT |
| | SIZING CALCULATION USES 14 OCCUPANTS FOR THE MADERA |
| | MODEL. PLEASE EXPLAIN HOW THE OCCUPANT LOAD WAS |
| | DERIVED. FBC 107.2.1 |
| | |
| | 5) THE ENERGY FORM FOR THE MADERA MODEL SPECIFIES |
| | 31,000 BTU/HR ( 9KW) HEAT STRIP AND THE MECHANICAL PLAN |
| | HAS 5 KW. PLEASE CLARIFY. FBC 107.2.1 |
| | |
| | 6) THE END UNITS TYPICALLY REQUIRE LARGER HEATING AND |
| | COOLING LOADS THAN THE UNITS IN BETWEEN. THEY HAVE AN |
| | EXTRA EXTERIOR WALL WITH WINDOWS. REVIEW THE |
| | CALCULATIONS TO DETERMINE WHY ALL OF THE UNITS HAVE THE |
| | SAME LOADS. FBC 107.2.1 |
| | |
| | 7) IN ORDER TO REDUCE PLAN REVIEW TIMES AND PROVIDE |
| | CLARIFICATION, PLEASE SUBMIT A RESPONSE LETTER |
| | INDICATING HOW EACH OF THE REVIEW COMMENTS HAS BEEN |
| | ADDRESSED. |
| | |
| | |
| | |
| | |