| Date |
Text |
| 2015-03-04 05:13:23 | 1) SHOW THE REQUIRED CLEANOUT AT THE JUNCTION OF THE | | | BUILDING DRAIN AND BUILDING SEWER PER THE 2010 FL. | | | BLDG. CODE, RESIDENTIAL, SEC.P3005.2.7. | | | 2) SHOW THE REQUIRED VENT FOR THE KITCHEN AND | | | LAVATORY.WPB AMEND. TO 2010 FPC SEC. 107.2.1. | | | 3) SUBMIT A SLAB REPAIR DETAIL FOR THE REPLACEMENT OF | | | THE CONCRETE TO INSURE THE STRUCTURAL INTEGRITY OF THE | | | SLAB.2010 FBCR SEC.P2603.1. | | | 4) INDICATE ON THE PLAN THE LENGTH & WIDTH OF THE AREA | | | OF THE CONCRETE REPAIR.WPB AMEND. TO 2010 FPC SEC. | | | 107.2.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|