| 2015-06-23 17:28:54 | RESIDENTIAL (R3) ALTERATION/ADDITION SECOND BUILDING |
| | REVIEW COMMENTS. |
| | CODE: 2010 FBC. |
| | |
| | 1- ENERGY CALCULATIONS SUBMITTED: |
| | A) CONDITIONED FLOOR AREA IS INCORRECT.. ENERGY |
| | CALCULATIONS ARE FOR THE FIRST FLOOR ALTERATION. AREA |
| | SHOWN IS NOT INCLUDING THE NEW ENCLOSED DINING ROOM. |
| | REVISE AS REQUIRED. SEC. 103.2.1.1.2 OF 2010 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | B) RAISED FLOOR AREA IS INCORRECT. COORDINATE WITH ITEM |
| | 1A ABOVE. SEC. 103.2.1.1.2 OF 2010 FBC-ENERGY |
| | CONSERVATION. |
| | |
| | C) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. (PERMIT |
| | CAN NOT BE ISSUED WITHOUT THIS CODE COMPLIANCE |
| | CERTIFICATION. SEE SEC. 103.2.3.2 OF 2010 FBC-ENERGY |
| | CONSERVATION). |
| | |
| | D) ROOF INFORMATION ON PAGE 2 OF 5 IS INCORRECT. THIS A |
| | FLAT ROOF. IT'S NOT A METAL ROOF. THE METAL ROOF IS ON |
| | THE MANSARDS ONLY AND IS NOT PART OF THE BUILDING |
| | THERMAL ENVELOPE. REVISE AS REQUIRED. SEC. 103.2.1.1.2 |
| | OF 2010 FBC-ENERGY CONSERVATION |
| | |
| | E) COMPLETE THE CHECKLIST ON PAGE 5 OF 5. SEC. 103.2.2 |
| | OF 2010 FBC-ENERGY CONSERVATION |
| | |
| | IMPORTANT: LABEL FOR WINDOWS AND DOORS U-FACTOR AND |
| | SHGC FACTOR WILL BE REQUIRED AT TIME OF INSPECTION WHEN |
| | THE ENERGY CALCULATIONS ARE NOT USING THE DEFAULT |
| | FACTOR. SEC. 303.1.3 OF 2010 FBC-ENERGY CONSERVATION |
| | |
| | 2- PLANS TO SPECIFY WALL, CEILING AND CRAWL SPACE |
| | INSULATION. COORDINATE WITH INFORMATION ON ENERGY |
| | CALCULATIONS. SEC. 103.2.2 OF 2010 FBC-ENERGY |
| | CONSERVATION. (REPEAT COMMENT. IT'S NOT THE |
| | CONTRACTOR'S RESPONSIBILITY. IT'S PART OF THE |
| | CONSTRUCTION DOCUMENTS. ) |
| | |
| | 3- NEED CARBON MONOXIDE ALARMS INSTALLED WITHIN 10 FEET |
| | OF EACH ROOM USED FOR SLEEPING AS REQUIRED BY SEC. R315 |
| | OF 2010 FBC-RESIDENTIAL. (REPEAT COMMENT. IT DOESN'T |
| | HAVE TO BE WORK TO BE DONE IN THE BEDROOMS. THE |
| | HABITABLE AREA OF THE FIRST FLOOR WAS INCREASED). |
| | |
| | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | DCA RULE 9N-3 FOR: |
| | A) HURRICANE SHUTTERS AND PROVIDE COMPLETE INSTALLATION |
| | SCHEDULE. NOA 11-1013.12 SUBMITTED FOR SINGLE HUNG |
| | WINDOWS WITHOUT IMPACT GLASS. NEW WINDOWS REQUIRE |
| | IMPACT PROTECTION. SEC R301.2.1.2 OF 2010 |
| | FBC-RESIDENTIAL. (REPEAT COMMENT. NOT ADDRESSED). |
| | |
| | B) SINGLE CABANA DOOR (MODEL CD290). PROVIDE COMPLETE |
| | APPROVED PRODUCT APPROVAL. INFORMATION SUBMITTED IS NOT |
| | AN APPROVED PRODUCT APPROVAL. PROVIDE THE MIAMI-DADE |
| | NOA NUMBER OR FLORIDA PRODUCT APPROVAL NUMBER. IF THERE |
| | IS NONE, THEN MANUFACTURER MAY APPLY FOR LOCAL PRODUCT |
| | APPROVAL. CONTACT ME (JULIO GOMEZ) FOR MORE INFORMATION |
| | REGARDING LOCAL PRODUCT APPROVAL PROCESS. (REPEAT |
| | COMMENT. NOT ADDRESSED). |
| | |
| | 5- DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT |
| | APPROVALS AS REQUIRED BY SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE REPLACE AND REMOVE ANY REVISED DRAWING. |
| | SUBMIT OLD COPY FOR REFERENCE. |
| | |