Plan Review Notes
Plan Review Notes For Permit 15030075
Permit Number 15030075
Review Stop P
Sequence Number 1
Notes
Date Text
2015-04-04 08:35:231) SHOW THE RELOCATED WATER HEATER ON THE PLAN. HOT
 WATER SHALL BE SUPPLIED TO THE STRUCTURE PER THE 2010
 FBCR SEC.P2801.1.
 2) THE HOT WATER SYSTEM SHALL BE PROVIDED WITH A MEANS
 FOR CONTROLLING THERMAL EXPANSION PER SEC. P2903.4.
 3) INDICATE ON THE PLAN IF THE WATER HEATER IS ELECTRIC
 OR GAS.
 4) IF THE WATER HEATER HAS BEEN RELOCATED TO THE 2ND
 FLOOR THEN A PAN AND PAN DRAIN WILL BE REQUIRED FOR THE
 INSTALLATION. FBCR P2801.5,P2803.6.1.
  